Ademco 4110DL Program Sheet

Version Info v6 and above are capable of paging and duress is user code 8

Main chip on panel should show N7185V3 (V3 and above is v6 or higher)

Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 500ma Aux output

2A Siren output

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

  1. Display will return to normal once upload is finished

Keypad Address (6128/6150 keypads only, this panel does not support 6139 or 6160 alpha keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter address 31

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

  5. Press * to exit

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = Enable

  1. = Enable

  1. = Enable

(Not available on older 4110DL's) 1 = Enable

  1. = Siren sounds at end of exit delay

(Not available on older versions) 1 = Enable

  1. = 8 minutes

  2. = 12 minutes

  3. = 16 minutes

  1. = Entry/Exit

4 = Interior/PIR

6 = 24 hr Silent (Holdup)

  1. = 24 hr Auxiliary (Medical)

(Hardwire smoke detectors must use this zone) 10 = Interior w/Delay (not available on older versions)

  1. = Fire Panic

6 = Silent Panic

7 = Audible Panic

8 = 24 hr Auxiliary (Medical)

9 = Fire without Timeout

Exit Delay = Entry + 15 seconds 2 = 30 seconds

3 = 45 seconds

4 = 60 seconds

  1. = 90 seconds

  1. = 10ms

End Phone Number with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Pager not available on older 4110DL, pager will not work if Account starts with 0)

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = 3/1, 4/1 Radionics Standard

  2. = 4/2 Ademco L/S Standard

  3. = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

  1. = Sescoa

  1. = Enable

  1. = 24 Hours

  2. = Weekly

To Primary Phone To Secondary Phone

0 = All Reports Backup only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

The following values are only available with 4110DL Rev 6 and higher, use 6 if programming Pagers

  1. = All reports except Open/Close Alarms, Open/Close, Troubles

  2. = All reports Alarms, Troubles

  3. = All reports Alarms, Open/Close, Troubles

  4. = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles

(Not available on older 4110DL's) I _1 _I Zone 96 3 & # (Audible Panic)

(Not available on older 4110DL's) 1 = Unlimited

#15 = Answer Machine over-ride