Ademco 4110 Vantage Program Sheet

Report Format 4/2, this panel CANNOT report Contact ID format

4/2 Signals

Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 500ma Aux output

2A Siren output

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

4. Display will return to normal once upload is finished

Keypad Address (6128/6150 keypads only, this panel does not support 6139 or 6160 alpha keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter address 31

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

  5. Press * to exit

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

Zone Page TECH1 Click HERE for List of what below programming will report

  1. = Enable

  1. = Enable

  1. = Enable

  1. = 8 minutes

  2. = 12 minutes

  3. = 16 minutes

  1. = Entry/Exit

  1. = Instant/Perimeter

  1. = Trouble by Day

  1. = 24 hr Audible (Police)

(Hardwire smoke detectors must use this zone) 9 = Fire without Timeout

  1. = Fire Panic

6 = Silent Panic

7 = Audible Panic

8 = 24 hr Auxiliary (Medical)

9 = Fire without Timeout

Exit Delay = Entry + 15 seconds 2 = 30 seconds

3 = 45 seconds

  1. = 10ms

End Phone with * # + 11 = *

# + 12 = #

# + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = 3/1, 4/1 Radionics Standard

  2. = 4/2 Ademco L/S Standard

  3. = 4/2 Radionics Standard

6 = 4/2 Ademco Express

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

  1. = DTMF Dialing

  2. = Pulse Dialing, CS on Watts Line

  3. = DTMF Dialing, CS on Watts Line

  1. = Enable

(Panel cannot be called into for download, tech must enter CODE + # + 1 to send to you)