Ademco 4111XM/First Alert FA150C Program Sheet

Enter Program 1. 4111 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 500ma Aux output

2A Siren output

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

4. Display will return to normal once upload is finished

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter address 31

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0 "

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0 "

  5. Press * to exit

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing RF receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = Enable

  1. Sensors are added as hardwire zones 10 to 18 1 = 5700 (4281) Receiver

4281L receiver adds 4 zones, 4281M and 4281H add 8 2 = 5800 (5881) Receiver

  1. = Enable

If using old 5700 series wireless this must match sensor dip switches

Also used with 5804BD keyfobs and 5827BD Keypads

  1. = 4219 Zone Expander

  2. = 4229 Zone/Relay Expander

  3. = 4204 Relay Module

  1. = Enable

  1. = No Fire Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

Exit Delay = Entry + 15 seconds 2 = 30 seconds

3 = 45 seconds

  1. = 10ms

End Phone Number with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = DTMF Dialing

  2. = Pulse Dialing, CS on Watts Line

  3. = DTMF Dialing, CS on Watts Line

  1. = 3/1, 4/1 Radionics Standard

  2. = 4/2 Ademco L/S Standard

  3. = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  1. = Enable

  1. = Enable

  2. = Yes for RF Arming (Keyfobs)

  1. = 10 ms

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Enter Zone to program (01 to 96) (* for next, # for previous menu)

Tech_201000000090.gif Hardwire Zones 01 to 08

Smoke Detectors Zone 05 only

4219/4229 Expander Zones 10 to 17

Police Panic Zone 07

Duress Zone 08

Receiver Trouble Zone 09

Wireless Zones 10 to 32

Fire Panic Zone 95

Medical Panic Zone 96

2. This shows current summary of Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

3. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled 08 = 24 hour Aux/Medical

  1. = Delay Zone 09 = Fire

  2. = Delay 2 Zone 10 = Interior Delay

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

  6. = 24 hour Silent/Holdup 23 = No Alarm Response

  7. = 24 hour Police Panic

4. Program Partition of Zone (* for next, # for previous menu)

Tech_201000000093.gif 1 = Partition 1

2 = Partition 2

5. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (10 in first section gives a report of A0)

Hardwire Zones will advance to step 9, for Wireless Zones continue

(If it doesn't go to next steps check if Receiver has been programmed in *22)

6. Enter type of Sensor

Tech_201000000095.gif 3 for Supervised RF (most sensors are RF)

4 for Un-Supervised RF

5 RF Button Type (Keyfobs/Panics etc)

7. Enter Loop number (* for next, # for previous menu)

Tech_201000000096.gif

Door Switch Internal switch Loop 2, external hardwire sensor Loop 1

Glassbreak Loop 1

Smoke Detectors Loop 1

Motions Loop 1

Keyfobs Bottom Right Button = Loop 1

(Each button counts as 1 zone) Top Right Button = Loop 2

Top Left Button = Loop 3

Bottom Left Button = Loop 4

8. Learning Sensor

Tech_201000000097.gif

Press 1 and trip sensor twice (Serial number cannot be manually entered)

Tech_201000000098.gif

9. This is the new programming of sensor (* for next, # for previous menu)

Tech_201000000099.gif

10. Normally press 0 to return to start or 1 if if customer has 6139 keypad

Tech_201000000100.gif

To delete a Zone set Zone Type as 00 then * until "Delete Sensor?", press 1 to delete

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

I _0 _I Partition 2

I _0 _I Partition 2

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Device to program (01 to 04) (* for next, 00 to exit)

    Tech_201000000101.gif

  2. This shows summary of current Device START programming (* for next, # for previous menu)

    Tech_201000000102.gif
(What starts the Device)

  1. This shows summary of current Device STOP programming (* for next, # for previous menu)

    Tech_201000000103.gif
(What stops the Device)

  1. Enter what Device will do when activated (* for next, # for previous menu)

    Tech_201000000104.gif
0 = No Response (or skip)

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Continuous Pulse On/Off

5. Enter what will start the Device (optional) (* for next, # for previous menu)

Tech_201000000105.gif 0 = Not Used (or skip)

  1. = on an Alarm

  2. = on a Zone Fault (or Keyfob button)

  3. = on a Trouble

6. Enter Zone List from *81 which STARTS Device (optional) (* for next, # for previous menu)

Tech_201000000106.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

7. Enter Zone Type that will START the Device (optional) (* for next, # for previous menu)

Tech_201000000107.gif 00 = Not Used (or skip) 31 = End of Exit Time

  1. = Entry/Exit Zone 32 = Start of Entry Time

03 = Perimeter/Instant Zone 33 = Any Burglar Alarm

04 = Interior Follower/Motions 34 = Code + # + 7 Key Entry

05 = Trouble by Day/Alarm by Night 35 = Code + # + 8 Key Entry

06 = 24 hour Silent/Holdup 36 = Bell Timeout or Disarm

07 = 24 hour Police Panic 37 = 2x Bell Timeout or Disarm

08 = 24 hour Aux/Medical 38 = Chime

09 = Fire 39 = Any Fire Alarm

10 = Interior Delay 40 = Bypassing

20 = Arm-Stay 41 = AC Power Failure

21 = Arm-Away 42 = System Low Battery

22 = Disarming

8. Enter which Partition will START this Device (Optional) (* for next, # for previous menu)

Tech_201000000108.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

9. Enter Zone List that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000109.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

10. Enter Zone Type that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000110.gif

11. Enter which Partition will STOP this Device (optional) (* for next, # for previous menu)

Tech_201000000111.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

12. This shows summary of new Device START programming (* for next, # for previous menu)

Tech_201000000112.gif

13. This shows summary of new Device STOP programming (* for next, # for previous menu)

Tech_201000000113.gif

14. If this is an X-10 Device enter 1, if not enter 0 (* for next, # for previous menu)

Tech_201000000114.gif

15. Enter next Device to program or 00 to exit

Tech_201000000101.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Zone List to program (01 to 04) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

  2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000116.gif
Multiple Zones can be added (example: 01* 03* 25*etc)

  1. If deleting a Zone List enter (01 to 04) or 0 to skip (* for next, # for previous menu)

    Tech_201000000117.gif

  2. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu)

    Tech_201000000118.gif

4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu)

Tech_201000000119.gif Multiple Zones can be deleted (example: 01* 03* 25*etc)

  1. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. to #15 = Rings to Answer

#15 = Answer Machine Over-ride