Ademco 4120XM Program Sheet

Enter Program 1. 4140 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97, answer YES if using alpha keypads

Compatibility

Power Ratings 700ma Aux output

2.8A Siren output

Keypad Address (6128/6150 keypads only, this panel does not support 6139 or 6160 alpha keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter address 31

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0 "

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0 "

  5. Press * to exit

Go-No Go Test (Verifies adequate RF by reducing RF receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

4. Display will return to normal once upload is finished

Hex Program Hex A = 10 B = 11 C = 12 D = 13 E = 14 F = 15

I _? _I _? _I Zone 2 01 = Entry/Exit 1

I _? _I _? _I Zone 3 02 = Entry/Exit 2

I _? _I _? _I Zone 4 03 = Instant

I _? _I _? _I Zone 5 04 = Interior

I _? _I _? _I Zone 6 05 = Day Zone

I _? _I _? _I Zone 7 06 = Holdup

I _? _I _? _I Zone 8 07 = Police

08 = Medical

I _? _I _? _I Zone 10 10 = Interior/Delay

I _? _I _? _I Zone 11

I _? _I _? _I Zone 12

I _? _I _? _I Zone 13

I _? _I _? _I Zone 14

I _? _I _? _I Zone 15

I _? _I _? _I Zone 16

I _? _I _? _I Zone 18

I _? _I _? _I Zone 19

I _? _I _? _I Zone 20

I _? _I _? _I Zone 21

I _? _I _? _I Zone 22

I _? _I _? _I Zone 23

I _? _I _? _I Zone 24

& Panics I _? _I _? _I Zone 26

I _? _I _? _I Zone 27

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _9 _I 1 & * / A Panic Key (Keypad Fire)

I _0 _I _8 _I 3 & # / C Panic Key (Keypad Medical)

I _0 _I _7 _I * & # / B Panic Key (Keypad Police)

  1. = Fast (10ms)

  1. = Enable

  1. = 1/2 second siren at end of Exit Delay #1

  1. = Enable

  1. = Siren sounds after 4 hours of AC loss

  1. = Random Report 10 - 40 Minutes

  1. = Enable

  1. = More than 1 Alarm per Arming Period

  1. = Voltage Output on Pin 6 of TB2 Header

  1. = No report if another signal recently sent

  1. - 024 Hrs

  1. = Yes

  1. = # + 2 = Away Arm

# + 3 = Stay Arm

# + 4 = Maximum Arm

# + 7 = Instant Arm

  1. = Touch-Tone

(Example 9 is 09*)

(Example 1234 is 01 02 03 04) Hex B = 11 C = 12 D = 13 E = 14 F = 15

(12 digits, end with *) # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(15's Default CSID to Factory)

I _1 _I System Shutdown 1 = Enable

I _0 _I Not Used

I _1 _I Remote Bypass

I _1 _I Remote Disarm

I _1 _I Remote Arm

I _1 _I Upload Programming

I _1 _I Download Programming

  1. to 64 Zone that cannot be bypassed

  1. = Enable

  1. = Normally Closed

  1. = 11 seconds

  2. = 30 seconds

  1. = Enable

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

I _0 _I Secondary 1 = Enable

  1. = Sescoa

  1. = Enable

  1. = Expanded

  1. = Expanded

I _1 _I _1 _I Zone 1 I _0 _I _0 _I Zone 1

I _1 _I _1 _I Zone 2 I _0 _I _0 _I Zone 2

I _1 _I _1 _I Zone 3 I _0 _I _0 _I Zone 3

I _1 _I _1 _I Zone 4 I _0 _I _0 _I Zone 4

I _1 _I _1 _I Zone 5 I _0 _I _0 _I Zone 5

I _1 _I _1 _I Zone 6 I _0 _I _0 _I Zone 6

I _1 _I _1 _I Zone 7 I _0 _I _0 _I Zone 7

I _1 _I _1 _I Zone 8 I _0 _I _0 _I Zone 8

I _1 _I _1 _I Zone 9 I _0 _I _0 _I Zone 9

I _1 _I _1 _I Zone 10 I _0 _I _0 _I Zone 10

I _1 _I _1 _I Zone 11 I _0 _I _0 _I Zone 11

I _1 _I _1 _I Zone 12 I _0 _I _0 _I Zone 12

I _1 _I _1 _I Zone 13 I _0 _I _0 _I Zone 13

I _1 _I _1 _I Zone 14 I _0 _I _0 _I Zone 14

I _1 _I _1 _I Zone 15 I _0 _I _0 _I Zone 15

I _1 _I _1 _I Zone 16 I _0 _I _0 _I Zone 16

I _0 _I _0 _I Zone Restore

I _0 _I _0 _I Zone Trouble

I _0 _I _0 _I Zone Trouble Restore

I _0 _I _0 _I Zone Bypass

I _0 _I _0 _I Zone Bypass Restore

I _1 _I _1 _I Zone 17 I _0 _I _0 _I Zone 17

I _1 _I _1 _I Zone 18 I _0 _I _0 _I Zone 18

I _1 _I _1 _I Zone 19 I _0 _I _0 _I Zone 19

I _1 _I _1 _I Zone 20 I _0 _I _0 _I Zone 20

I _1 _I _1 _I Zone 21 I _0 _I _0 _I Zone 21

I _1 _I _1 _I Zone 22 I _0 _I _0 _I Zone 22

I _1 _I _1 _I Zone 23 I _0 _I _0 _I Zone 23

I _1 _I _1 _I Zone 24 I _0 _I _0 _I Zone 24

I _1 _I _1 _I Zone 25 I _0 _I _0 _I Zone 25

I _1 _I _1 _I Zone 26 I _0 _I _0 _I Zone 26

I _1 _I _1 _I Zone 27 I _0 _I _0 _I Zone 27

I _1 _I _1 _I Zone 28 I _0 _I _0 _I Zone 28

I _1 _I _1 _I Zone 29 I _0 _I _0 _I Zone 29

I _1 _I _1 _I Zone 30 I _0 _I _0 _I Zone 30

I _1 _I _1 _I Zone 31 I _0 _I _0 _I Zone 31

I _1 _I _1 _I Zone 32 I _0 _I _0 _I Zone 32

I _0 _I _0 _I Zone Restore

I _0 _I _0 _I Zone Trouble

I _0 _I _0 _I Zone Trouble Restore

I _0 _I _0 _I Zone Bypass

I _0 _I _0 _I Zone Bypass Restore

I _1 _I _1 _I Zone 33 I _0 _I _0 _I Zone 33

I _1 _I _1 _I Zone 34 I _0 _I _0 _I Zone 34

I _1 _I _1 _I Zone 35 I _0 _I _0 _I Zone 35

I _1 _I _1 _I Zone 36 I _0 _I _0 _I Zone 36

I _1 _I _1 _I Zone 37 I _0 _I _0 _I Zone 37

I _1 _I _1 _I Zone 38 I _0 _I _0 _I Zone 38

I _1 _I _1 _I Zone 39 I _0 _I _0 _I Zone 39

I _1 _I _1 _I Zone 40 I _0 _I _0 _I Zone 40

I _1 _I _1 _I Zone 41 I _0 _I _0 _I Zone 41

I _1 _I _1 _I Zone 42 I _0 _I _0 _I Zone 42

I _1 _I _1 _I Zone 43 I _0 _I _0 _I Zone 43

I _1 _I _1 _I Zone 44 I _0 _I _0 _I Zone 44

I _1 _I _1 _I Zone 45 I _0 _I _0 _I Zone 45

I _1 _I _1 _I Zone 46 I _0 _I _0 _I Zone 46

I _1 _I _1 _I Zone 47 I _0 _I _0 _I Zone 47

I _1 _I _1 _I Zone 48 I _0 _I _0 _I Zone 48

I _0 _I _0 _I Zone Restore

I _0 _I _0 _I Zone Trouble

I _0 _I _0 _I Zone Trouble Restore

I _0 _I _0 _I Zone Bypass

I _0 _I _0 _I Zone Bypass Restore

I _1 _I _1 _I Zone 49 I _0 _I _0 _I Zone 49

I _1 _I _1 _I Zone 50 I _0 _I _0 _I Zone 50

I _1 _I _1 _I Zone 51 I _0 _I _0 _I Zone 51

I _1 _I _1 _I Zone 52 I _0 _I _0 _I Zone 52

I _1 _I _1 _I Zone 53 I _0 _I _0 _I Zone 53

I _1 _I _1 _I Zone 54 I _0 _I _0 _I Zone 54

I _1 _I _1 _I Zone 55 I _0 _I _0 _I Zone 55

I _1 _I _1 _I Zone 56 I _0 _I _0 _I Zone 56

I _1 _I _1 _I Zone 57 I _0 _I _0 _I Zone 57

I _1 _I _1 _I Zone 58 I _0 _I _0 _I Zone 58

I _1 _I _1 _I Zone 59 I _0 _I _0 _I Zone 59

I _1 _I _1 _I Zone 60 I _0 _I _0 _I Zone 60

I _1 _I _1 _I Zone 61 I _0 _I _0 _I Zone 61

I _1 _I _1 _I Zone 62 I _0 _I _0 _I Zone 62

I _1 _I _1 _I Zone 63 I _0 _I _0 _I Zone 63

I _1 _I _1 _I Zone 64 I _0 _I _0 _I Zone 64

I _0 _I _0 _I Zone Restore

I _0 _I _0 _I Zone Trouble

I _0 _I _0 _I Zone Trouble Restore

I _0 _I _0 _I Zone Bypass

I _0 _I _0 _I Zone Bypass Restore

I _0 _I _0 _I Zone 81 4219 Supervisory I _0 _I _0 _I Zone 81

I _0 _I _0 _I Not Used I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 83 4219 Tamper I _0 _I _0 _I Zone 83

I _0 _I _0 _I Not Used I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 88 Receiver not hearing Transmitter I _0 _I _0 _I Zone 88

I _0 _I _0 _I Zone 89 Receiver not Responding/ Bad Con I _0 _I _0 _I Zone 89

I _0 _I _0 _I Zone 90 Receiver not hearing Transmitter I _0 _I _0 _I Zone 90

I _0 _I _0 _I Zone 91 Receiver not Responding/ Bad Con I _0 _I _0 _I Zone 91

I _1 _I _1 _I Zone 92 Duress I _0 _I _0 _I Duress

I _0 _I _0 _I Zone 97 Polling Loop Short I _0 _I _0 _I Zone 97

I _1 _I _1 _I Zone 95 1 & * / A Fire Panic Key I _0 _I _0 _I Zone 95

I _1 _I _1 _I Zone 96 3 & # / C Medical Panic Key I _0 _I _0 _I Zone 96

I _1 _I _1 _I Zone 99 * & # / B Police Panic Key I _0 _I _0 _I Zone 99

I _0 _I _0 _I Zone Restore

I _0 _I _0 _I Zone Trouble

I _0 _I _0 _I Zone Trouble Restore

I _0 _I _0 _I Zone Bypass

I _0 _I _0 _I Zone Bypass Restore

  1. = Enable

  1. = Enable

I _0 _I _0 _I Close I _0 _I _0 _I Close

I _0 _I _0 _I Open I _0 _I _0 _I Open

I _1 _I _1 _I Low Battery I _0 _I _0 _I Low Battery

I _0 _I _0 _I Low Battery Restore I _0 _I _0 _I Low Battery Rest

I _1 _I _1 _I AC Loss I _0 _I _0 _I AC Loss

I _0 _I _0 _I AC Loss Restore I _0 _I _0 _I AC Loss Rest

I _0 _I _0 _I Test I _0 _I _0 _I Test

I _0 _I _0 _I Power I _0 _I _0 _I Power

I _1 _I _1 _I Cancel I _0 _I _0 _I Cancel

I _0 _I _0 _I Program Tamper I _0 _I _0 _I Program Tamper

  1. = 3 beeps

  1. = 16 seconds

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 2nd Level of Programming press *94 then enter * + 2-digits, to exit back to 1st Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *00 Open/Close Report Enable I _0 _I User 17 0 = Disable

I _0 _I User 18 1 = Enable

I _0 _I User 19

I _0 _I User 20

I _0 _I User 21

I _0 _I User 22

I _0 _I User 23 to 70

  1. *01 Zone Types for Zones 28 to 89 I _? _I _? _I Zone 28 00 = Disabled

I _? _I _? _I Zone 29 01 = Entry/Exit 1

I _? _I _? _I Zone 30 02 = Entry/Exit 2

I _? _I _? _I Zone 31 03 = Instant

I _? _I _? _I Zone 32 04 = Interior

05 = Day Zone

  1. *02 Zone Types for Zones 22 to 40 I _? _I _? _I Zone 33 06 = Holdup

I _? _I _? _I Zone 34 07 = Police

I _? _I _? _I Zone 35 08 = Auxiliary/Medical

I _? _I _? _I Zone 36 09 = Fire

I _? _I _? _I Zone 37 10 = Interior Delay

I _? _I _? _I Zone 38

I _? _I _? _I Zone 39

I _? _I _? _I Zone 40

  1. *03 Zone Types for Zones 41 to 48 I _? _I _? _I Zone 41

I _? _I _? _I Zone 42

I _? _I _? _I Zone 43

I _? _I _? _I Zone 44

I _? _I _? _I Zone 45

I _? _I _? _I Zone 46

I _? _I _? _I Zone 47

I _? _I _? _I Zone 48

  1. *04 Zone Types for Zones 49 to 56 I _? _I _? _I Zone 49

I _? _I _? _I Zone 50

I _? _I _? _I Zone 51

I _? _I _? _I Zone 52

I _? _I _? _I Zone 53

I _? _I _? _I Zone 54

I _? _I _? _I Zone 55

I _? _I _? _I Zone 56

  1. *05 Zone Types for Zones 57 to 64 I _? _I _? _I Zone 57

I _? _I _? _I Zone 58

I _? _I _? _I Zone 59

I _? _I _? _I Zone 60

I _? _I _? _I Zone 61

I _? _I _? _I Zone 62

I _? _I _? _I Zone 63

I _? _I _? _I Zone 64

  1. *06 Not Used

  1. *07 Not Used

  1. *08 Receiver & Voice Module Superv I _0 _I _0 _I Zone 81 4219 Not Communicating

I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 83 4219 Tamper

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 88 2nd Receiver

  1. *09 1st & 2nd Receiver Troubles I _? _I _? _I Zone 89 2nd Receiver

I _? _I _? _I Zone 90 1st Receiver

I _? _I _? _I Zone 91 1st Receiver

  1. *10 to 1*17 Not Used

  1. *18 Enable Wireless Zones 1 to 8 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *19 Enable Wireless Zones 9 to 16 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *20 Enable Wireless Zones 17 to 24 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *21 Enable Wireless Zones 25 to 32 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *22 Enable Wireless Zones 33 to 40 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *23 Enable Wireless Zones 41 to 48 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *24 Enable Wireless Zones 49 to 56 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *25 Enable Wireless Zones 57 to 63 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *26 First RF Receiver Select I _0 _I 0 = Disable

  1. = Enable

  1. *27 Second RF Receiver Select I _0 _I 0 = Disable

  1. = Enable

  1. *28 RF Low Battery Sound I _0 _I 0 = When Disarmed

  1. = Immediate

  1. *29 RF Low Battery Report Enable I _1 _I 0 = Disable

  1. = Enable

  1. *30 RF RCVR Check-In Interval I _0 _I _6 _I 00 = Disabled

  2. -15 x2 Hours

  1. *31 RF Transmitter Check in Interval I _1 _I _2 _I 00 = Disabled

  2. to 15x2 Hours

  1. *32 RF Receiver Type I _? _I 0 = None or 4280 Receiver

  1. = 4281 Receiver

  1. *33 Touch-Tone W/Rotary Backup I _1 _I 0 = Disable

  1. = Rotary dial if 1st Touch-Tone fails

  1. *34 Comm Split Report Selection I _1 _I 0 = Disable

  1. = Alarms to Primary, others Secondary

  2. = O/C and Test reports to Secondary, others Primary

  1. *35 to 1*39 Not Used

  1. *40 Armed Stay Report 1st Digit I _0 _I _0 _I 00 = No Report

  1. *41 Armed Stay Report 2nd Digit I _0 _I _0 _I 00 = No Report

  1. *44 RF Keypad Tamper Detect I _0 _I 0 = Disable

  1. = Enable

  1. *45 Enable Exit Beeps I _1 _I 0 = Disable

  1. = Enable

  1. *46 Aux Output Enable I _0 _I 0 = Ground Start

  1. = O/C Trigger Term 9

  2. = Not Used

  3. = Zone 1 EOLR

  1. *47 Chime on External Sounder I _0 _I 0 = Disable

  1. = Enable

  1. *48 Wireless Keypad Disable I _0 _I 0 = Disable

  1. = Enable

  1. *49 Suppress Trouble Sound for RF I _1 _I 0 = Disable

  1. = Enable

  1. *50 Babysitter Code User 22 I _1 _I 0 = Disable

  1. = Enable

  1. *51 4281 House ID (5700 wireless) I _0 _I _0 _I 00 to 31

  1. *52 Cancel Report Restriction I _0 _I 0 = Timeout

  1. = None

  1. *53 Download Callback I _1 _I 0 = Yes

  1. = No Callback

  1. *54 High Security Mode I _0 _I 0 = 4-digit Codes

  1. = 6-digits

  1. *55 to 1*56 Not Used

  1. *57 Trigger Mode I _1 _I 0, 1, 2, 3 (See Manual)

  1. *58 4219 First Zone Number I _0 _I _0 _I 00 = Disable

09 to 57 = Zone 09 to 57