Ademco 5110XM/First Alert FA2000C Program Sheet

Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 20)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98

Or

2. *99 if needing to re-enter programming later by Code + 8 + 00

Power Ratings 350ma Aux output

  1. A Siren output

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter address 31

  4. Press * to save and exit

Keypad Address (6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

  5. Press * to exit

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = Enable

  1. = 8 minutes

  2. = 12 minutes

  3. = 16 minutes

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

  1. = Supervisory on Open and Short

  1. = Tone-Dial

  1. = Alarm

  2. = Smoke Detector Reset

  3. = Battery Save

  4. = Alarm (silenced by Code + #67)

End Phone Number with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)

  1. = Touch-Tone Dial

  1. = 3/1, 4/1 Radionics Standard

  2. = 4/2 Ademco L/S Standard

  3. = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

  1. = Alarms, Restore All Other Reports

  2. = All Reports except Test Test

  3. = Alarms, Restore All Reports

  4. = All Reports except Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  1. = 24 Hours

  2. = Weekly

  1. = Sescoa

Zone 1 to 5 = Hardwire Zones

Zone 6 = Bell Supervisory

Zone 7 = * & #

Zone 10 = Earth Ground

Zone 11 = Main Dialer

Zone 12 = Backup Dialer

Zone 13 = Aux Relay

Zone 95 = 1 & *

Zone 96 = 3 & #

1. Enter zone to program then * or 00 to quit

Tech_201000000136.gif

2. This is summary of current Zone programming (* for next, # for previous menu)

Tech_201000000137.gif

3. Enter Zone Type (* for next, # for previous menu)

Tech_201000000138.gif 00 = Zone Disabled/Deleted 16 = Fire with Verification

06 = 24 Hr Silent 17 = Fire Waterflow

07 = 24 Hr Audible 18 = Fire Supervisory

08 = 24 Hr Auxiliary (Medical) 19 = 24 Hr Trouble

09 = Fire without Verification

4. Enter 10 in 1st 2 digits for Report Code (* for next, # for previous menu)

Tech_201000000139.gif (10 in first section gives Report Code A0)

5. " Keypad shows new summary of programming or be back to "Enter zone number"

Tech_201000000140.gif

6. Press 0 to skip or 1 if system will use a 6139 Alpha keypad

Tech_201000000141.gif

7. Enter next Zone or 00 to exit

Tech_201000000136.gif

  1. = Delay set in field *78

  1. = Automatic Silence when Waterflow ceases

  1. = Steady

I _1 _I Backup 1 = Enable

Fire Walk Test Start I _ 0 _I _ 0 _I

Fire Walk Test End I _ 0 _I _ 0 _I

Off-Norm Dialer Test I _ 0 _I _ 0 _I

I _ 1 _I Zone 2 1 = Bell

I _ 1 _I Zone 3 2 = Aux Relay

I _ 1 _I Zone 4 3 = Bell & Aux Realy

I _ 1 _I Zone 5

I _ 0 _I Zone 6

I _ 0 _I Zone 7

Bell/Aux Relay Activation I _ 0 _I Zone 10 1 = Bell

I _ 0 _I Zone 11 2 = Aux Relay

I _ 0 _I Zone 12 3 = Bell & Aux Realy

I _ 1 _I Zone 95

I _ 0 _I Zone 96

  1. to #15 = Rings to Answer

#15 = Answer Machine Over-ride