Ademco LynxR/LynxR-EN v11 Program Sheet

Power Ratings 30mA - Piezo output terminals 10 & 11

120mA - Bell output terminals 11 & 12

Enter Program 4112 + 8 + 8 + 8

(Voice Prompt)

Tech_201000000260.gif

Voice Prompts "Add Sensors"

"Delete Sensors"

"First Central Station Phone Number" (Not seen with Monitronics panels)

"First Central Station Account Number"

"Second Central Station Phone Number" (Not seen with Monitronics panels)

"Second Central Station Account Number"

"Template" (Loads default panel info, use 1 if needed)

"Expert Programming Mode" (Standard programming mode)

Enter Program 4112 + 8 + 0 + 0 (Display should show 20)

(Standard) or Power down then back up and press * and # within 1 minute

(If exiting programming you can re-enter within 1 minute by pressing * and #)

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98

OR

2. *99 if needing to re-enter programming later by Code + 8 + 00

OR

3. Press ESCAPE to return to Voice Prompt Programming then ESCAPE again to exit

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 8

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

  1. = Enable

  1. = Backlight Off after 10 seconds

  1. = Enable

(5827, 5827BD keypads and 5804BD Keyfobs) 01 to 31

  1. = G 7 = H 8 = I 9 = J #10 = K

#11 = L #12 = M #13 = N #14 = O #15 = P

  1. = Enable (Program in *81 Zone List 3

  1. = Enable

  1. = January 08 = August

  2. = February 09 = September

  3. = March #10 = October

  4. = April #11 = November

  5. = May #12 = December

  6. = June

Start/End Weekend Number 2 = 2nd Weekend

3 = 3rd Weekend

4 = 4th Weekend

5 = Last Weekend

6 = Next to Last Weekend

  1. = 3rd from Last Weekend

  1. = 1 per Arming period

  1. = Enable

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

I _ 1 _I Quick Exit 1 = Enable

  1. = 1/2 second siren if armed by keypad or RF Keyfob/Keypad

  2. = 1/2 second siren if armed by RF keyfob/Keypad

  1. = Enable

(If 9 is needed to dial add here)

End with * # + 11 = * # + 12 = # # + 13 = 2 second pause

(B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)

(For Pagers or "Follow Me" Feature)

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

4 = Pulse with Speaker Phone (Lynx-EN only)

5 = DTMF with Speaker Phone (Lynx-EN only)

6 = Pulse/Watts/Speaker Phone (Lynx-EN only)

7 = DTMF/Watts/Speaker Phone (Lynx-EN only)

I _ 7 _I Secondary 1 = 3/1, 4/1 Radionics Standard

(2-Way Voice available only with Contact ID) 2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID (4-digit Account Numbers)

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

To Primary Phone To Pager (*46)

  1. = All reports except Open/Close (Pager) Alarms/Open/Close/Trouble Users 5 - 8, Keyfobs 26-33

  2. = All reports Alarms/Troubles

  3. = All reports Alarms/Open/Close/Trouble Users 5 to 8, keyfobs 26-33

  4. = All reports except Open/Close Alarms/Open/Close for Users 5 to 8 or wireless

Arm/disarm keyfob zones 34-41, users 1 to 4 and

Keyfobs 26-33 do not send open/close reports

To Primary Phone To End User Voice Prompt (*46)

  1. = All except Open/Close Alarms/Open/Close/Trouble Users 5 - 8, Keyfobs 26-33

  2. = All Reports Alarms/Trouble

  3. = All Reports Alarms/Open/Close/Trouble Users 5 - 8, Keyfobs 26-33

  4. = All except Open/Close Open/Close

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  3. = Monthly

(sends after exit program 1 = 6 Hours

mode or after downloading) 2 = 12 Hours

3 = 18 Hours

  1. = Sescoa

  1. = 1 Day 4 = 90 Days

  2. = 7 Days 5 = 180 Days

  3. = 27 Days 6 = 365 Days

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Enter Zone to program (01 to 99) or 00 to exit (* for next, 00 to exit)

Tech_201000000261.gif Hardwire Zone Zone 01

Wireless Zones Zones 02 to 25

Keyfob Zones Zones 26 to 41

Duress Code Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

Lynx Defaults Zone 2 = Delay Zone on Loop 2, Voice description = "Front Door"

Zone 3 = Delay Zone on Loop 2, Voice description = "Back Door Door"

Zone 4 = Instant Zone on Loop 2, Voice description = "Window"

Zone 5 = Interior on Loop 1, Voice description = "Motion Detector"

Zone 26 = 21 Arm Away Loop 3 Zone 30 = 21 Arm Away Loop 3

Zone 27 = 22 Disarm Loop 2 Zone 31 = 22 Disarm Loop 2

Zone 28 = 20 Arm Stay Loop 4 Zone 32 = 20 Arm Stay Loop 4

Zone 29 = 23 No Alarm Loop 1 Zone 33 = 23 No Alarm Loop 1

2. Enter Zone Type (* for next, # for previous menu)

Tech_201000000262.gif 00 = Zone Disabled/Deleted 08 = 24 hour Aux/Medical

  1. = Delay Zone 09 = Fire

  2. = Secondary Delay Zone 10 = Interior Delay

  3. = Perimeter/Instant 20 = Arm-Stay

  4. = Interior Follower/Motions 21 = Arm-Away

  5. = Trouble by Day/Alarm by Night 22 = Disarm

  6. = 24 hour Silent/Holdup 23 = No Alarm Response

  7. = 24 hour Police Panic 24 = Silent Burglary

3. Enter 10 for Report Code (* for next, # for previous menu)

Tech_201000000263.gif

if programming Panics or Duress display will move back to step 1, sensors continue to step 4

4. Enter RF Loop Type (* for next, # for previous menu)

Tech_201000000264.gif 3 = RF (Door/Motions/Glassbreaks/Smokes)

4 = UR (some Remote Panic Buttons)

5 = BR (Keyfobs and Panic Buttons)

5. Enter Loop Number (0 to 4) (* for next, # for previous menu)

Tech_201000000265.gif (0 displays "F" delete sensor screen, see end of this section)

Door Switch External wired connector = Loop 1

Internal reed switch = loop 2

Glassbreak Loop 1

Smoke Detectors Loop 1

Motions Loop 1

Keyfobs Bottom Right Button = Loop 1

(Each button is 1 zone) Top Right Button = Loop 2

Top Left Button = Loop 3

Bottom Left Button = Loop 4

5a. If this appears sensor has been previously learned

Tech_201000000266.gif

6. Sensor Menu (* for next, # for previous menu)

Press 1 to go to step 7 and enter Serial Number

Press 2 to copy last serial number entered (Used for keyfobs)

Press 3 to view existing serial number 1 digit at a time (Only if sensor previously learned and IA L displays)

Press 9 to move to "F" (Delete Sensor) screen (Then press 1 to delete existing serial number)

Press * to continue to Step 10 Zone Descriptor screen

Press # to move back to Step 5 Loop Number screen

Press 0 to skip to step 10 and enter Zone Descriptors

Tech_201000000267.gif

7. If 1 is pressed enter Serial Number now then * (* for next, # skips back to step 6)

Tech_201000000268.gif

8. Serial Number displays, press * to accept, # backs up to step 7

Tech_201000000269.gif

9. Display shows serial learned, press * for next

Tech_201000000270.gif

9a. Activate Sensor to confirm (optional), press * for next

Tech_201000000271.gif

10. Press 1 to enter Zone Descriptor, 0 skips to next zone

Tech_201000000272.gif

11. Enter 1st word with # + 2-digit word

Tech_201000000273.gif 6 saves and moves to step 12 (Keypad speaks each word as entered)

  1. saves and moves to next zone

12. Enter 2nd word with # + 2-digit word

Tech_201000000274.gif 6 saves and moves to step 13 (Keypad speaks each word as entered)

8 saves and moves to next zone

13. Enter 3rd word with # + 2-digit word

Tech_201000000275.gif 6 or 8 saves new Voice Descriptor (Keypad speaks new Voice Descriptor)

and moves to next Zone at step 1

00 ½ sec pause 07 First Floor 16 North 75 Three

82 Alarm 45 Five 58 Nursery 76 Transmitter

32 Attic 08 Floor 59 Office 77 Two

  1. Baby 46 Four 60 One 78 Upstairs

33 Back 47 Front 17 Outside 26 Utility

34 Basement 48 Garage 61 Patio 79 Utility Room

35 Bathroom 49 Guest Room 62 Police 27 West

36 Bedroom 09 Gun 18 Pool 80 Window

83 Check 50 Hall 63 Rear 28 Yard

37 Delay Door 10 Inside 19 Room 81 Zero

38 Den 51 Kitchen 64 Second Floor 86 Zones

  1. Detector 11 Laundry 65 Seven 29 1 ST

  2. Dining 52 Laundry Room 20 Shed 30 2 ND

39 Dining Room 12 Library 21 Shop 31 3 RD

  1. Door 13 Living 66 Side 70 Custom Word #1

40 Downstairs 53 Living Room 67 Silent Police 71 Custom Word #2

  1. Driveway 14 Main 68 Six 72 Custom Word #3

  2. East 15 Master 69 Sliding 73 Custom Word #4

41 Eight 54 Master Bedroom 22 Smoke 74 Custom Word #5

42 Emergency 55 Medical 23 South 99 Blank/Erase

43 Family Room 84 Message 24 Storage

87 Fire 56 Motion Detector 85 System

44 Fire Detection 57 Nine 25 Third Floor

14. Enter next Zone to program (01 to 99) or 00 to exit

Tech_201000000276.gif

Delete Sensor

1. At "A" Zone Number (step 1) screen enter zone to delete (01 to 41) then *

2. At "B" Zone Type (step 2) screen enter 00 then *

or enter 0 at "E" Loop Number screen (step 5) then *

3. Press * until "F" Delete Sensor screen appears

Tech_201000000277.gif

4. If 00 was entered at Zone Type (B) screen press 1 to delete sensor and move to next sensor programming

if 0 was entered at Loop Number (E2 or E2L) screen press 1 to delete only the serial number and move to 1C screen

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. = RF Jam Detect, no Report

  2. = RF Jam + Report

I _ 0 _I Stay

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Example: to open garage door

  1. Select Device 01 in step 2

  2. Select 1 in step 3 to close for 2 seconds to activate X-10 PowerFlash at garage door opener

  3. Select 2 in step 4 to enable keyfob button fault to activate X-10 PowerFlash

  4. Select a Zone List which has the keyfob button entered (programmed in *81)

  5. Bypass steps 6 and 7, program keyfob button as Type 23 (No Alarm Response)

Note: To turn a lamp on and off with keyfob 2 buttons must be used, one for ON and one for OFF

1. Press 0 to exit or 1 to enter *80 programming

Tech_201000000278.gif

2. Enter 2-digit X-10 Device number (01 to 08) (* for next, 00 to exit)

Tech_201000000279.gif (set by X-10 module dials)

By default schedule 8 is

Action = 2 (Close and stay closed)

Start Zone Type = 33 (Start on any burglar alarm)

Stop Zone Type = 36 (Stop on siren timeout or disarm)

3. Enter what X-10 device will do or 0 to skip (* for next, # for previous)

Tech_201000000280.gif 0 = No Response/Skip

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Pulse On and Off

For X-10 PowerHorn to function it must be set to Pulse On and OFF!

4. Enter START Event Type (Type of event to trigger device) (* for next, # for previous)

Tech_201000000281.gif 0 = Not Used/Skip

  1. = Alarm

  2. = Fault (Zone or Keyfob button)

  3. = Trouble

5. Enter START Zone List (List programmed in *81) (* for next, # for previous)

Tech_201000000282.gif 0 = Not Used/Skip

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

6. Enter START Zone Type (Optional) (* for next, # for previous)

Tech_201000000283.gif 00 = Not Used/Skip 22 = Disarming

  1. = Delay Zone 31 = End of Exit Time

  2. = Secondary Delay Zone 32 = Start of Entry Time

  3. = Perimeter/Instant 33 = Any Burglar Alarm

  4. = Interior Follower/Motions 36 = At Bell Timeout or Disarm

  5. = Trouble by Day/Alarm by Night 38 = Chime

  6. = 24 hour Silent/Holdup 39 = Any Fire Alarm

  7. = 24 hour Police Panic 40 = Bypassing

08 = 24 hour Aux/Medical 42 = System Low Battery

09 = Fire 43 = Communication Failure

10 = Interior Delay 52 = Kissoff

20 = Arm-Stay 58 = Duress

21 = Arm-Away

7. Enter STOP Zone List (List programmed in *81) (* for next, # for previous)

Tech_201000000284.gif 0 = Not Used/Skip

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

8. Enter STOP Zone Type (Optional) (* for next, # for previous)

Tech_201000000285.gif (see above Zone Types)

9. Enter next 2-digit Device number (01 to 08) or 00 to exit

Tech_201000000279.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Press 1 to enter zone list programming, 0 to exit

Tech_201000000286.gif

2. Enter Zone List to program (* for next, 00 exits)

Tech_201000000287.gif Zone List 1 = X-10

Zone List 2 = X-10

Zone List 3 for Chime By Zone *26

3. Enter Zone to add to Zone List then * then 00 for step 4 (* for next, 00 exits)

Tech_201000000288.gif Multiple Zones can be added (example: 01* 03* 25*etc)

4. To delete this Zone List press 1, to skip to step 5 press 0 (* for next, 00 exits)

Tech_201000000289.gif

5. To delete Zone in this List press 1, to skip to step 6 press 0 (* for next, 00 exits)

Tech_201000000290.gif

5a. If 1 was selected enter Zone to delete then *, end with 00

Tech_201000000291.gif Multiple Zones can be deleted (example: 01* 03* 25*etc)

6. Enter next Zone List to program or 00 to exit

Tech_201000000287.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Press 1 to enter mode programming, 0 to exit

Tech_201000000292.gif

2. Enter Zone to add Voice Description (01 to 99) (* for next, 00 exits)

Tech_201000000293.gif

3. Enter 1st word with # + 2-digit Descriptor

Tech_201000000294.gif 6 saves and moves to step 4 (Keypad speaks each word as entered)

8 saves and moves to next zone

4. Enter 2nd word with # + 2-digit Descriptor

Tech_201000000295.gif 6 saves and moves to step 5 (Keypad speaks each word as entered)

8 saves and moves to next zone

5. Enter 3nd word with # + 2-digit Descriptor

Tech_201000000295.gif 6 or 8 to save and finish (Keypad speaks entire Voice Descriptor)

6. Enter next Zone to add Voice Description (01 to 99) or 00 to exit

Tech_201000000293.gif

00 1/2 sec pause 14 Fire 28 Motion 42 Window

  1. Alarm 15 Floor 29 Office 43 Yard

  2. Attic 16 Front 30 Patio 44 Zones

  3. Baby 17 Garage 31 Pool 45 1st

  4. Back 18 Gun 32 Room 46 2nd

  5. Basement 19 Hall 33 Shed 47 3rd

  6. Bathroom 20 Inside 34 Shop 70 Custom Word 1

  7. Bedroom 21 Kitchen 35 Side 71 Custom Word 2

08 Check 22 Laundry 36 Sliding 72 Custom Word 3

09 Den 23 Library 37 Smoke 73 Custom Word 4

10 Detector 24 Living 38 Storage 74 Custom Word 5

11 Dining 25 Main 39 System 99 Blank

12 Door 26 Master 40 Upstairs

13 Emergency 27 Message 41 Utility

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Press 1 to enter mode programming, 0 to exit

Tech_201000000296.gif

2. Enter Custom Word to program (70 to 74) or 00 to exit (* for next, 00 exits)

Tech_201000000297.gif

3. Press * + # to begin recording

4. Keypad beeps 3 times, after 3rd beep speak message (Recording length is 1.5 seconds)

5. Press # to re-record

Press 6 to save and move back to to step 2

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

(For Macros see "Basic Commands") 1 = Aux key sends message to Pager

(For PIN's, 800 blocks etc * = # + 11, # = # + 12, 2 second pause = # + 13)

(Logs into Event Buffer) 1 = Logs Alarm/Restore

2 = Logs Trouble/Restore

4 = Logs Bypass/Restore

  1. = Open/Close

#15 = Logs all

1 = AVM 2-Way & Remote Phone Control

For non 2-way systems select 0 or 2 2 = Remote Phone Control only

For 2-way systems select 1 or 4 4 = AVM 2-Way Audio only

  1. = Unlimited per Armed period

1 = Last digit flexible

2 = Last 2-digits flexible

3 = Last 3-digits flexible

  1. to 14 = Rings before answer

15 = Answering Machine over-ride

Scheduling (All Lynx-REN, Lynx-RSP and revision 6+ Lynx-R panels)

  1. Enter Master or Installer Code + # + 64

  2. Enter Schedule to program (1 to 8) then * for next, # exits

Tech_201000000247.gif 1 to 6 are for Users, 7 to 8 only for Installer

  1. Enter Event which will occur then * for next, # exits

Tech_201000000248.gif 0 = No Event Selected

  1. = Activate X-10 Device

  2. = Latch Key Report (sounds if not disarmed by specific time)

  3. = Automatic Stay Arming

  4. = Voice Reminder Announcement

  5. = Alarm Clock (sounds until button press)

4. Enter Hour to Start Event then * for next, # exits

Tech_201000000249.gif 00 to 12

5. Enter 0 for AM or 1 for PM then * for next, # for previous display

Tech_201000000250.gif

  1. Enter Minute to Start Event then * for next, # for previous display

Tech_201000000251.gif

  1. Enter Start Day of Event then * for next, # for previous display

Tech_201000000252.gif

If Events 3, 4 and 5 were programmed display will return to step 1

If events 1 and 2 are being programmed display will continue to step 8

  1. Enter Hour to Stop Event then * for next, # for previous display

Tech_201000000253.gif

  1. Enter 0 for AM or 1 for PM then * for next, # for previous display

Tech_201000000254.gif

  1. Enter Minute to Stop Event then * for next, # for previous display

Tech_201000000255.gif

  1. Enter Stop Day of Event then * for next, # for previous display

Tech_201000000256.gif

If not programming X-10 Devices display returns to step 1

  1. Enter X-10 Device to perform Event then * for next, # for previous display

Tech_201000000257.gif Device 1 to 8

Display will move back to step 1, press # to exit