Ademco SL150 Program Sheet

Information This is a version of the Vista-20SE

Standard Honeywell/Ademco keypads may or may not work on this system

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

  1. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (31)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up

  2. Hold 1 & 3 for 3 seconds until flashing " - - 0 0" (if "DA" shows power down then up again)

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

4. Press * to exit

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = 5800 Receiver

4 = 5800 with RF Jamming

  1. = Enable

(5804BD, 5827 and 5827BD wireless) 01 to 31

  1. = 4219 8-Zone Expander

  2. = 4229 Zone Expander Module

  3. = 4204 Relay Module

  1. = Yes (Program Zones in Zone List 3)

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

  1. st digit = 1 to 9

  2. nd digit = # + 11 for * or # + 12 for #

  1. = Enable

  1. = Enable

  1. = Enable

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

  1. = Enable

  1. = Enable

  1. = Enable

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

I _ 7 _I Secondary 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  3. = Monthly

  1. = 6 Hours

  2. = 12 Hours

  3. = 18 Hours

  1. = Sescoa

  1. to 15 (F) = 1 to 15 x15 Seconds

  1. = Long Range Radio First

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif This example shows Zone 10

Hardwire Sensors Zone 01 to 08

2-wire Smokes Zone 01 only (up to 16 smoke detectors)

  1. wire Smokes Zone 02 to 08

4219/4229 Zone Expander Zone 10 to 17

Keyswitch Zone 07

Receiver Tamper/Trouble Zone 09

Wireless Zone 10 to 39 (Depending on receiver capacity)

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

3. This shows summary of current Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

4. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled/Deleted 10 = Interior with Delay

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 15 = Medical

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 64 = One Button Page

09 = 24 Hr Supervised Fire 77 = Keyswitch (see *30)

5. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (10 in first section gives report of A0)

5a. Enter Response of Hardwired Zone 1 to 8 (* for next, # for previous menu)

Tech_201000000189.gif 0 = 10msec

(Hardwire Zones only) 1 = 350msec (Default)

2 = 700msec

Hardwire Zones advance to step 9, Wireless Zones continue with step 6

6. Enter type of Sensor (* for next, # for previous menu)

Tech_201000000190.gif 2 = Auxiliary Wired (4229 Zone Expander)

3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

7. Serial Number Programming (* for next, # for previous menu)

Press 1 then enter serial number or trip sensor twice, Loop number will also be learned

Tech_201000000173.gif This shows ready to learn

Tech_201000000174.gif Serial and Loop number is manually entered here

or learned by tripping twice (keypad will beep)

(Serial number sticker is on sensor)

8. If "Set to Confirm" was selected while first entering *56 this will appear

Tech_201000000191.gif Trip sensor again to confirm

If incorrect serial number was learned this will appear

Tech_201000000192.gif

(This can be used to find out a serial number if sticker was removed)

9. This shows summary of new sensor programming (* for next, # for previous menu)

Tech_201000000099.gif

10. Press 0 for next sensor or 1 to enter Alpha descriptions

Tech_201000000100.gif

11. Enter next sensor or 00 then * or # to exit *56 menu

Tech_201000000090.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) then *

Tech_201000000176.gif

3. Enter Zone Type (Display moves to Report Code, # starts over)

Tech_201000000177.gif 00 = Zone Disabled/Deleted 10 = Interior with Delay

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 15 = Medical

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 64 = One Button Page

09 = 24 Hr Supervised Fire 77 = Keyswitch (see *30)

4. Display moves to Report Code, if needed enter 10 (Display moves to Sensor Type, # starts over)

Tech_201000000178.gif

A key moves right through fields if needed

B key moves left through fields if needed

C key copies previous Zone attributes

Hardwired Zones automatically skip to step 9, Wireless Zones continue with step 5

5. Enter Wireless sensor type then *

Tech_201000000179.gif 3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

6. If Wireless enter Serial Number or trip sensor twice (Keypad will beep twice as Sensor learns)

Tech_201000000180.gif

Tech_201000000181.gif

7. Enter Loop only if manually entering Serial Number (* for next, # for previous menu)

Tech_201000000182.gif

8. If "Set to Confirm" was selected while first entering *58 this will appear

Tech_201000000183.gif Trip sensor again to confirm

Tech_201000000184.gif This shows panel and sensor serials match

9. Enter next sensor or 00 then * or # to exit *58 menu

Tech_201000000185.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

I _ 0 _I Stay

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Relay to program (01 to 04) (* for next, 00 to exit)

    Tech_201000000160.gif
  1. to 02 for 4229 Relay Module/Zone Expander

  1. to 04 for 4204 Relay Module

  1. o 08 for X-10 Powerline Carrier

  2. This shows summary of current Relay START programming (* for next, # for previous menu)

    Tech_201000000161.gif
(What starts the Relay)

  1. This shows summary of current Relay STOP programming (* for next, # for previous menu)

    Tech_201000000162.gif
(What stops the Relay)

  1. Enter what Relay will do when activated (* for next, # for previous menu)

    Tech_201000000163.gif
0 = No Response (or skip)

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Continuous Pulse On/Off

5. Enter what will start the Relay (optional) (* for next, # for previous menu)

Tech_201000000164.gif 0 = Not Used (or skip)

  1. = on an Alarm

  2. = on a Zone Fault (or Keyfob button)

  3. = on a Trouble

6. Enter Zone List from *81 which STARTS Relay (optional) (* for next, # for previous menu)

Tech_201000000165.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

7. Enter Zone Type that will START the Relay (optional) (* for next, # for previous menu)

Tech_201000000166.gif 00 = Skip this step 24 = Silent Burglary

  1. = Delay Zone 31 = End of Exit Time

  2. = Secondary Delay Zone 32 = Start of Entry Time

  3. = Perimeter/Instant 33 = Any Burglar Alarm

  4. = Interior Follower/Motions 36 = At Bell Timeout or Disarm

  5. = Trouble by Day/Alarm by Night 38 = Chime

  6. = 24 hour Silent/Holdup 39 = Any Fire Alarm

  7. = 24 hour Police Panic 40 = Bypassing

08 = 24 hour Aux/Medical 41 = AC Power Failure

09 = Fire 42 = System Low Battery

10 = Interior Delay 43 = Communication Failure

14 = Carbon Monoxide 52 = Kissoff

15 = Medical 58 = Duress

20 = Arm-Stay 64 = 1-button Page

21 = Arm-Away 65 = Any Carbon Monoxide Alarm

22 = Disarming/Code + OFF

  1. Enter 0 here (not used) (* for next, # for previous menu)

    Tech_201000000487.gif

  2. Enter Zone List that will STOP the Relay (optional) (* for next, # for previous menu)

    Tech_201000000167.gif
0 = Not Used/Skip

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

10. Enter Zone Type that will STOP the Relay (optional) (* for next, # for previous menu)

Tech_201000000110.gif 00 = Skip this step 24 = Silent Burglary

  1. = Delay Zone 31 = End of Exit Time

  2. = Secondary Delay Zone 32 = Start of Entry Time

  3. = Perimeter/Instant 33 = Any Burglar Alarm

  4. = Interior Follower/Motions 36 = At Bell Timeout or Disarm

  5. = Trouble by Day/Alarm by Night 38 = Chime

  6. = 24 hour Silent/Holdup 39 = Any Fire Alarm

  7. = 24 hour Police Panic 40 = Bypassing

08 = 24 hour Aux/Medical 41 = AC Power Failure

09 = Fire 42 = System Low Battery

10 = Interior Delay 43 = Communication Failure

14 = Carbon Monoxide 52 = Kissoff

15 = Medical 58 = Duress

20 = Arm-Stay 64 = 1-button Page

21 = Arm-Away 65 = Any Carbom Monoxide Alarm

22 = Disarming/Code + OFF

11. Enter 0 here (not used) (* for next, # for previous menu)

Tech_201000000488.gif

12. This shows summary of new Relay START programming (* for next, # for previous menu)

Tech_201000000168.gif

13. This shows summary of new Relay STOP programming (* for next, # for previous menu)

Tech_201000000169.gif

14. Select if Relay or X-10 Device (* for next, # for previous menu)

Tech_201000000489.gif

15. Enter next Relay to program or 00 to exit

Tech_201000000160.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Zone List to program (01 to 03) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif
  1. = Zone List 1 (Standard X-10 or Relay Devices)

  2. = Zone List 2 (Standard X-10 or Relay Devices)

  3. = Zone List 3 (Standard X-10 or Relay Devices/Chime by Zone)

06 = Pager 1 Reporting

07 = Pager 2 Reporting

2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu)

Tech_201000000116.gif Multiple Zones can be added

(Example: 01* 03* 25*etc)

3. If deleting a Zone List enter (01 to 03) or 0 to skip (* for next, # for previous menu)

Tech_201000000117.gif

  1. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu)

    Tech_201000000118.gif

4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu)

Tech_201000000119.gif Multiple Zones can be deleted

(Example: 01* 03* 25*etc)

  1. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

I _ 0 _I Pager 2 1 = Opening/Closings for All Users

3 = Open/Close users 5 to 16, wireless

key zones entered in Zone list 6/7

4 = All alarms and Troubles

5 = All Alarms, Troubles, Open/Close

7 = All Alarms, Troubles, Open/Close

Users 5 to 16,, Wireless Zones in list 6/7

12 = Alarms & Troubles for Zones in list 6/7

13 = Alarms & Troubles for zones in list 6

Open/Close for all users

15 = All Alarms & Troubles for Zones in list 6/7

Open/Close users 5 to 16 and wireless keys

entered in Zone List 6/7

(Pin number, account etc)

  1. = Alarm/Restore

  2. = Trouble/Restore

4 = Bypass/Bypass Restore

8 = Open/Close

  1. = Macros

4 = AAV 2-Way Module

8 = Exit Delay Restart

12 = AAV 2-Way Module + Exit Delay Restart

14 = Enable All

  1. = KP Display

  2. = KP Display/Sounder

  3. = KP Display/Sounder/Device 2 starts

  1. = Unlimited per armed period

  1. to #15 = 1 to 15 rings before answer

#15 = Answer Machine over-ride