Ademco Via-16 Program Sheet

Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 500ma Aux output

2A Siren output

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

4. Display will return to normal once upload is finished

Keypad Address (6128/6150 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (31)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up

  2. Hold 1 & 3 for 3 seconds until flashing " - - 0 0" (if "DA" shows power down then up again)

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

4. Press * to exit

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = Enable

  1. = Enable

  1. = Enable

(Must match House ID of all 5700 series sensors) 01 to 31

  1. = Enable

  1. = Enable

  1. = Enable

  1. = 8 minutes

  2. = 12 minutes

  3. = 16 minutes

(Hardwire smoke detectors must use this zone) 1 = Entry/Exit

2 = Fire with timeout

  1. = Interior/PIR

  1. = 24 Hour Silent (Holdup)

  2. = 24 Hour Audible (Police Panic)

  3. = 24 hr Auxiliary (Medical)

  4. = Fire without timeout (Smokes)

Exit Delay = Entry + 15 seconds 2 = 30 seconds

3 = 45 seconds

4 = 60 seconds

5 = 90 seconds

  1. = 10ms

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = 3/1, 4/1 Radionics Standard

  2. = 4/2 Ademco L/S Standard

  3. = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

  1. = Sescoa

  1. = Enable

  1. = 24 Hours

  2. = Weekly

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

The following is only available with v6 and above panels, use 6 if programming Pagers

  1. = All reports except Open/Close Alarms, Open/Close, Troubles

  2. = All reports Alarms, Troubles

  3. = All reports Alarms, Open/Close, Troubles

I _1 _I 3 & # Fire (Audible, sends 96)

Wireless Zone Programming

Set sensor zone number dip switches to match zone type listed to the right and enter zone number in *76 to *91

Example: If 1st wireless zone is delay set zone dip switches to 10, in *76 enter 10 for zone and 10 for report code

If 2nd wireless zone is fire set zone dip switches to 48, in *76 enter 48 for zone and 10 for report code

I _ 1 _I _ 0 _I Report Code Zone 14 to 29 = Instant

Zone 30 to 47 = Interior/PIR

I _ 1 _I _ 0 _I Report Code Zone 56 to 61 = Day Zone

Zone 62 = 24 hr Audible

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

I _ 1 _I _ 0 _I Report Code

  1. = Unlimited

  1. to #15 = Rings to Answer

#15 = Answer Machine Over-ride