Ademco Vista-100/First Alert 1600C Program Sheet

Enter Program 1. 4140 or 5140 + 8 + 0 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

(If exiting programming you can re-enter within 1 minute by pressing * and #)

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Default Panel *97, answer YES if using alpha keypads

Power Ratings 1A Aux output standby 1.7A Aux output in alarm

  1. 7A each Siren output

Device Address All keypads, receivers and expanders must be addressed and added in #93 menu

Address 00 to 03 are pre-programmed as alpha keypads

Address first keypad as 00 to allow entry into programming

00 Alpha Keypad (cannot be changed)

  1. to 30 Keypads, zone expanders, wireless receivers etc

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (00 to 30)

  4. Press * to save and exit

(6128RF/6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0 "

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Enter new address (00 to 30) then * to exit back to flashing " -- 0 0 "

  5. Press * to exit

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Partition Notes (If system is Partitioned)

  1. Press *91

  2. Enter Partition (1 to 8)

  3. Enter location (all locations on this page marked (Partition Specific))

  4. Press *99 to return to regular panel programming

#93 Menu (All Zone programming is done here, enter #93 then ecycle through menus (Click to go to section))

Tech_201000000129.gif 1 enters, 0 moves to next menu (Serial Number Programming)

Tech_201000000492.gif 1 enters, 0 moves to next menu (Report Code Programming)

Tech_201000000481.gif 1 enters, 0 moves to next menu (Alpha Zone Programming)

Tech_201000000130.gif 1 enters, 0 moves to next menu (Device Programming)

Tech_201000000131.gif 1 enters, 0 moves to next menu (Output Relay Programming)

Tech_201000000482.gif 1 enters, 0 moves to next menu (Relay/Voice Descriptors)

Tech_201000000226.gif 1 enters, 0 moves to next menu (Custom Index)

Tech_201000000227.gif 1 enters, 0 moves to next menu (Under Construction)

Tech_201000000483.gif

Tech_201000000132.gif 1 exits #93 menu, 0 moves back to Zone Program

(Partition Specific)

(Partition Specific)

(Partition Specific)

(Partition Specific)

(Partition Specific)

  1. = Partition 1

to

8 = Partition 8

(Partition Specific) 1 = Enable

  1. = Enable

  1. = Enable

  1. = Random Report 10 - 40 Minutes

  2. = Random Report 6 to 12 hours

I _0 _I _0 _I 2nd Digit 2nd Digit = 11 (*) or 12 (#)

  1. = Enable

(Partition Specific) I _1 _I 996 3 & # 1 = Enable

I _1 _I 999 * & #

(Partition Specific) 1 = More than 1 Alarm per Arming Period

  1. = Ignore Tampers on Expansion Modules

  1. = Trigger Voltage to Pin 3 of J7 Header

  1. = No report sent if another signal was recently sent

  1. to 999 Hours

  1. = Enable

(Partition Specific) 1 = Enable

  1. = Touch-Tone

(Example 9 is 09*)

(Example 1234 is 01 02 03 04) Hex B = 11 C = 12 D = 13 E = 14 F = 15

(17 digits, end with *) # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(15's Default CSID to Factory)

I _1 _I Sys Shutdown 1 = Enable

I _0 _I Not Used

I _1 _I Remote Bypass

I _1 _I Remote Disarm

I _1 _I Remote Arm

I _1 _I Upload Enable

I _1 _I Download Enable

(Partition Specific) 01 to 87 that cannot be bypassed

(Partition Specific) 1 = Enable

  1. = Enable

  1. = Zones 3 to 8 require EOL Resistors

  1. = 11 seconds

  2. = 30 seconds

  1. = Wait for Dial Tone

  1. = Downloading Disable

  2. to 14 = Rings to Answer

15 = Answering Machine Over-Ride

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

I _0 _I Secondary 1 = Enable

  1. = Radionics

  1. = Enable

I _0 _I Restore 1 = Expanded

I _0 _I Bypass

I _0 _I Trouble

I _0 _I Open/Close

I _0 _I Low Battery

I _0 _I Restore 1 = Expanded

I _0 _I Bypass

I _0 _I Trouble

I _0 _I Open/Close

I _0 _I Low Battery

I _0 _I Zone Type 2 1 = Enable

I _0 _I Zone Type 3

I _0 _I Zone Type 4

I _0 _I Zone Type 5

I _0 _I Zone Type 6

I _0 _I Zone Type 7

I _0 _I Zone Type 8

I _0 _I Zone Type 10 1 = Enable

I _1 _I _2 _I Hours 00 to 23

I _0 _I _0 _I Minutes 00 to 59

(Partition Specific) 01 to 15 Alarms

(Partition Specific) I _1 _I Zn 96 Medical 1 = Enable

I _1 _I Zn 99 Police

I _1 _I Duress

(Partition Specific) 1 = Continuous during Entry Delay

(Partition Specific) 1 = 16 Seconds

  1. = At Bell Timeout

  2. = At Disarm

(Partition Specific) Hex B = 11, C = 12, D = 13, E = 14, F = 15

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 2nd Level of Programming press *94 then enter * + 2-digits, to exit back to 1st Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *17 Common Lobby I _0 _I 0 = Disable

  1. to 8 = Partition 1 to 8

  1. *18 Affects Lobby I _0 _I 0 = Does not affect Common Lobby

  1. = Affects Common Lobby

  1. *19 Arms Lobby I _0 _I 0 = Does not Arm Common Lobby

  1. = Arms Common Lobby

  1. *20 Exit Error Logic I _0 _I 0 = Disable

  1. = Bypass Faulted Zones after Arming

  1. *21 Exit Delay Reset I _0 _I 0 = Disable

  1. = Reset Delay 60 seconds after Zone Closes

  1. *28 RF Low Battery Sound I _0 _I 0 = When Disarmed

  1. = Immediate

  1. *29 RF Low Battery Report Enable I _1 _I 0 = Disable

  1. = Enable

  1. *30 RF RCVR Check-IN Interval I _0 _I _6 _I 00 = Supervision Disable

  2. to 15x2 Hours

  1. *31 RF Transmitter Check in Interval I _1 _I _2 _I 00 = Supervision Disable

  2. to 15x2 Hours

  1. *32 RF Receiver Type I _0 _I 0 = Supervision Disable

  1. = 4281 (5700 series wireless)

  2. = 5881 (5800 series wireless)

  1. *33 Touch-Tone with Rotary Backup I _1 _I 0 = Disable

  1. = Enable

  1. *34 Communication Split Report Selection I _0 _I 0 = Disable

  1. = Alarms Primary, others Secondary

  2. = O/C, Test Secondary, others Primary

  1. *42 Call Waiting Defeat I _0 _I 0 = Disable

  1. = Enable

  1. *43 Permanent Keypad Backlight I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

  1. *44 Wireless Keypad Tamper Detect I _0 _I 0 = Disable

  1. = Enable

  1. *45 Exit Delay Sounder I _1 _I 1 = Enable

(Partition Specific) 0 = Disable

  1. *47 Chime on Bell 1 I _0 _I 0 = Disable

(Partition Specific) 1 = Enable

  1. *48 Wireless Keypad Assignment I _0 _I 0 = Disable

  1. to 8 = Partition 1 to 8

  1. *49 Suppress TX Supervision Sound I _1 _I 0 = Enable

  1. = Disable

  1. *52 Send Cancel If Alarm + Off I _0 _I 0 = Within Bell Timeout

(Partition Specific) 1 = No Restriction

  1. *53 Download Callback Enable I _1 _I 0 = Callback Required

  1. = No Callback Required

  1. *57 Enable 5800 RF Button Global Arm I _0 _I 0 = Keyfob will not Global Arm

  1. = Follows Global User Settings

  1. *58 Enable 5800 RF Button Force Bypass I _0 _I 0 = Enable

  1. = Disable

  1. *60 Zone 5 Audio Alarm Verification I _1 _I 0 = Disabled

(Do not use Zone 5 if this option is enabled) 1 = 2-Way Voice Module used

  1. *70 Event Log Types I _ _I Alarm 0 = Disable Logging

I _ _I Check 1 = Enable Logging

I _ _I Bypass

I _ _I O/C

I _ _I System

I _ _I Test Report

  1. *71 12/24 Hour Time Stamp Format I _0 _I 0 = 12 Hour

  1. = 24 Hour (Military)

  1. *72 Event Log Printer Online I _0 _I 0 = Enable

  1. = Disable

  1. *73 Printer Baud Rate I _0 _I 0 = 1200 Baud

  1. = 300 Baud

  1. *74 Relay Timeout Minutes I _ _I _ _I _ _I 0 to 127 x2 minutes

  1. *75 Relay Timeout Seconds I _ _I _ _I _ _I 0 to 127 seconds

  1. *76 Access Control Relay for Partition I _ _I _ _I 00 = None

(Partition Specific) 01 to 16 = Relay used when Code + 0

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 3rd Level of Programming press *94 then enter * + 2-digits, to exit back to 2nd Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *00 Number of Partitions I _1 _I 1 to 8 = 1 to 8 Partitions

2*01 Daylight Savings Time I _0 _I _4 _I Start

Start/End Month I _1 _I _0 _I End

2*02 Daylight Savings Time I _1 _I Start 1 = 1st Weekend

Start/End Weekend I _5 _I End 2 = 2nd Weekend

  1. = 3rd Weekend

  2. = 4th Weekend

  3. = Last Weekend

  4. = Next to Last Weekend

  5. = 3rd from Last Weekend

2*05 Auto-Arm Delay I #15 I #15 = Auto-Arm Disabled

(Partition Specific) 1 to 14 x4 Minutes

2*06 Auto-Arm Warning Period I 00_I 00 = Instant at end of Arming Delay

(Partition Specific) 1 to 15 Minutes

2*07 Auto-Disarm Delay I #15 I 00 = Instant at end of Window

(Partition Specific) 15 = No Auto-Disarm

  1. to 14 x4 Minutes

  2. *08 Enable Force Arm for Auto-Arm I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*09 Open/Close Reports by Exception I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*10 Allow Disarm only during I _1 _I 0 = Disable

Arm/Disarm Window 1 = Enable

(Partition Specific)

2*11 Allow Disarm Outside Window I _1 _I 0 = Disable

If Alarm Occurs 1 = Enable

(Partition Specific)

2*17 Number of Codes Per Partition I _6 _I _9 _I Partition 1 01 to 69

Start/End Month I _0 _I _1 _I Partition 2 Total must be less than or equal to 70

2*18 Enable Goto For This Partition I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*19 Use Partition Descriptors I _1 _I 0 = Disable

  1. = Enable

  2. *20 Enable J7 Triggers by Partition I _1 _I 0 = Disable for displayed Partition

(Partition Specific) 1 = Enable for displayed Partition

2*21 Enable Supervision Pulses for I _ _I _ _I _ _I 0 = Disable

Long Range Radio Trigger Outputs F B S 1 = Enable

F = Fire

B = Burglary

S = Silent Panic/Duress

2*22 Display Fire Alarms of Other Partitions I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*23 Display Burg/Panics of Other Partitions I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*24 Display Troubles of Other Partitions I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 4th Level of Programming press *94 then enter * + 2-digits, to exit back to 3rd Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *00 Display Trouble instead of Check I _0 _I 0 = Check Displayed

  1. = Trouble Displayed

3*13 Supervisory N/O NC Selection I _0 _I 0 = Supervisory on Short, Trouble on Open

  1. = Supervisory on Short or Open

3*14 Waterflow Silence Option I _1 _I 0 = Silence on Code + OFF

  1. = Silence When Waterflow Restores

3*15 Alarm Bell Sound I _1 _I Bell 1 0 = Pulsed

I _0 _I Bell 2 1 = Steady

3*16 Delay for Zone Types 17 & 18 I _0 _I _0 _I 00 to 15 x2 Seconds

(Waterflow & Fire Supervisory)

3*17 Alternate Function (Tamper) Zone 6 I _0 _I 0 = Disable

  1. = Enable

3*18 Extended Delay for Types 17 & 18 I _0 _I 0 = Disable

  1. = Enable

3*19 Enable J2 Header Printer Port I _0 _I 0 = Pins 5 & 9 function per field 3*20

  1. = Pins 5 & 9 act as printer RXD & DTR

3*20 Trigger Outputs Selection I _0 _I 0 = LORRA full connection/Remote Sounder

  1. = LORRA limited conn./Keyswitch LED's

  2. = LORRA Fire only conn/5140LED

  3. *21 Max # of Dialer Attempts I _8 _I 1 to 8 Attempts

3*30 Dialer Selection I _1 _I Main Dialer 0 = Disable

(Main Dialer must be ON if cell primary) I _0 _I Backup Dialer 1 = Enable

3*31 Backup Dialer Touch-Tone/Rotary I _0 _I 0 = Rotary

  1. = Touch-Tone

3*50 Zone Type 16 to 18 Restores Enabled I _0 _I Zone Type 16 0 = Disable

I _0 _I Zone Type 17 1 = Enable

I _0 _I Zone Type 18

3*57 Bell 2 & Aux Relay Conf of Arm Ding I _0 _I 0 = Disable

(Partition Specific) 1 = Enable

3*58 Bell 2 & Aux Relay AC Loss Alarm I _0 _I Main Dialer 0 = Disable

I _0 _I Backup Dialer 1 = Enable

3*59 Bell 2 & Aux Relay Chime Annunciate I _0 _I Bell 2 0 = Disable

(Partition Specific) I _0 _I Relay 1 = Enable

3*60 Bell 2 & Aux Relay Timeout I _0 _I _0 _I Bell 2 00 = No Timeout

(Partition Specific) I _0 _I _0 _I Relay 01 to 15 x2 Minutes

3*61 Aux Relay Function I _1 _I 0 = Trouble/Supervisory

  1. = Alarm, Silenced by Code + OFF

  2. = Smoke Detector Reset

  3. = Battery Save

  4. = Alarm, Silenced by Code + # + 67

3*82 Enable Burg Features on Partition 1 I _1 _I 0 = Disable

(0 disables Stay/Away/Max/Test/Chime functions) 1 = Enable

3*85 Enable Fire & System Zone Bypass I _1 _I 0 = Disable

Zone Types 9, 16, 17, 18, Zones 70 to 77 1 = Only Installer Code can Bypass

(Partition 1 only) 2 = Only Installer and Master Code can Bypass