Ademco Vista-20AMT Program Sheet

This is a Vista-20SE without partitioning

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Keypad Address (6128/6139/6150/6160 keypads, these may not work on this proprietary panel)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (31)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

4. Press * to exit

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = 5800 Receiver

  1. = Enable

(for 5804BD and 5827BD Keypad/Keyfobs) 01 to 31

  1. = 4219 8-Zone Expander

  2. = 4229 Zone Expander Module

  3. = 4204 Relay Module

  1. = Enable Zones to chime in Zone List 3

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

(Allows access to Voice module) 1st digit = 1 to 9

2nd digit = # + 11 for * or # + 12 for #

  1. = Enable

  1. = Enable

  1. = Enable

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

  1. = Enable

  1. = Enable

  1. = Enable

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = DTMF (No Watts Line)

  2. = Pulse

  3. = DTMF (Watts Line)

I _ 7 _I Secondary 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  6. = All reports except Open/Close Alarms, Open/Close, Troubles

  7. = All reports Alarms, Troubles

  8. = All reports Alarms, Open/Close, Troubles

  9. = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  3. = Monthly

  1. = 6 Hours

  2. = 12 Hours

  3. = 18 Hours

  1. = Sescoa

1. Depending on version of system one of these may appear

(If "Program Tool?" press 0, if "Set to Confirm?" shows press 1)

Tech_201000000170.gif Tech_201000000171.gif

2. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif

Hardwire Zones 01 to 08

4219/4229 Zone Expander Zones 10 to 17

Receiver Tamper/Trouble Zone 09

Wireless Zones 10 to 39 (Depends on receiver capacity)

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

3. This shows current summary of Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

4. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled 09 = Fire

  1. = Delay 1 10 = Interior Delay

  2. = Delay 2 20 = Arm-Stay (RF only)

  3. = Perimeter/Instant 21 = Arm-Away (RF only)

  4. = Interior Follower/Motions 22 = Disarm (RF only)

  5. = Trouble by Day/Alarm by Night 23 = No Alarm Response

  6. = 24 hour Silent/Holdup 24 = Silent Burglary

  7. = 24 hour Police Panic

08 = 24 hour Aux/Medical

5. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (Enter 10 in first section if using Contact ID)

6. Enter only if Hardwire Zone 1 to 8 (* for next, # for previous menu)

Tech_201000000189.gif 0 = 10msec

1 = 350msec

2 = 700msec

Hardwire Zones will advance to step 10, for Wireless Zones continue

7. Enter type of Sensor

Tech_201000000095.gif 3 for Supervised RF (most sensors are RF)

4 for Un-Supervised RF

5 RF Button Type (Keyfobs/Panics etc)

8. Enter Loop number (Some older systems) (* for next, # for previous menu)

Tech_201000000096.gif

Door Switch Internal switch Loop 2

External hardwire sensor Loop 1

Glassbreak Loop 1

Smoke Detectors Loop 1

Motions Loop 1

Keyfobs Bottom Right Button = Loop 1

(Each button counts as 1 zone) Top Right Button = Loop 2

Top Left Button = Loop 3

Bottom Left Button = Loop 4

9. Serial Number Programming

Tech_201000000172.gif

Press 1 and either enter serial number or trip sensor twice, 1st to learn, 2nd to confirm

Note: Serial numbers found on sticker on of sensor, if not, learn by tripping sensor

Tech_201000000173.gif This shows ready to learn

Tech_201000000174.gif This shows Serial Number either manually entered or learned

Tech_201000000175.gif This shows sensor was confirmed by activating twice

10. This is the new programming of sensor (* for next, # for previous menu)

Tech_201000000099.gif

11. Normally press 0 to return to start or 1 if if customer has 6139 keypad

Tech_201000000100.gif

To delete a Zone set Zone Type as 00 then * until "Delete Sensor?", press 1 to delete

I _ 0 _I Away

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Relay to program (01 to 08) (* for next, 00 to exit)

    Tech_201000000160.gif
  1. to 02 for 4229 Relay Module/Zone Expander

  1. to 04 for 4204 Relay Module

  1. to 08 for X-10 Powerline Carrier

  2. This shows summary of current Relay START programming (* for next, # for previous menu)

    Tech_201000000161.gif
(What starts the Relay)

  1. This shows summary of current Relay STOP programming (* for next, # for previous menu)

    Tech_201000000162.gif
(What stops the Relay)

  1. Enter what Relay will do when activated (* for next, # for previous menu)

    Tech_201000000163.gif
0 = No Response (or skip)

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Continuous Pulse On/Off

5. Enter what will start the Relay (optional) (* for next, # for previous menu)

Tech_201000000164.gif 0 = Not Used (or skip)

  1. = on an Alarm

  2. = on a Zone Fault (or Keyfob button)

  3. = on a Trouble

6. Enter Zone List from *81 which STARTS Relay (optional) (* for next, # for previous menu)

Tech_201000000165.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

7. Enter Zone Type that will START the Relay (optional) (* for next, # for previous menu)

Tech_201000000166.gif 00 = Not Used (or skip) 24 = Silent Burglary

  1. = Entry/Exit Zone 31 = End of Exit Time

03 = Perimeter/Instant Zone 32 = Start of Entry Time

04 = Interior Follower/Motions 33 = Any Burglar Alarm

05 = Trouble by Day/Alarm by Night 36 = Bell Timeout or Disarm

06 = 24 hour Silent/Holdup 38 = Chime

07 = 24 hour Police Panic 39 = Any Fire Alarm

08 = 24 hour Aux/Medical 40 = Bypassing

09 = Fire 41 = AC Power Failure

10 = Interior Delay 42 = System Low Battery

20 = Arm-Stay 43 = Communication Failure

21 = Arm-Away 52 = Kissoff

22 = Disarming 58 = Duress

8. Enter Zone List that will STOP the Relay (optional) (* for next, # for previous menu)

Tech_201000000167.gif 0 = Not Used

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

9. Enter Zone Type that will STOP the Relay (optional) (* for next, # for previous menu)

Tech_201000000110.gif

10. This shows summary of new Relay START programming (* for next, # for previous menu)

Tech_201000000168.gif

11. This shows summary of new Relay STOP programming (* for next, # for previous menu)

Tech_201000000169.gif

12. Enter next Relay to program or 00 to exit

Tech_201000000160.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Zone List to program (01 to 03) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

  2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000116.gif
Multiple Zones can be added (example: 01* 03* 25*etc)

  1. If deleting a Zone List enter (01 to 03) or 0 to skip (* for next, # for previous menu)

    Tech_201000000117.gif

  2. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu)

    Tech_201000000118.gif

4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu)

Tech_201000000119.gif Multiple Zones can be deleted (example: 01* 03* 25*etc)

  1. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. = Alarm/Restore

  2. = Trouble/Restore

4 = Bypass/Bypass Restore

8 = Open/Close

F (#15) All Options Enabled

  1. = AAV 2-way module enable

(4 turns off siren during 2-way)

  1. = Keypad Display

  2. = Keypad Display/Sounder

  3. = Keypad Display/Sounder/Device 2 starts

  1. = Unlimited per Armed period

  1. to 14 = Rings before answer

15 = Answering Machine over-ride