Ademco Vista-20HW Program Sheet

Information This panel does not support wireless sensors

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (31)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up

  2. Hold 1 & 3 for 3 seconds until flashing " - - 0 0 " (if "DA" shows power down then up again)

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0 "

4. Press * to exit

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

I _ 1 _I Partition 2 1 = Enable

I _ 0 _I _ 0 _I Partition 2 1 = Enable

  1. = 4219 8-Zone Expander

  2. = 4229 Zone Expander Module

  3. = 4204 Relay Module

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

(Allows access to Voice module) 1st digit = 1 to 9

2nd digit = # + 11 for * or # + 12 for #

  1. = Enable

  1. = Enable

  1. = Enable

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

I _ 6 _I _ 0 _I Partition 2

I _ 3 _I _ 0 _I Partition 2

I _ 3 _I _ 0 _I Partition 2

I _ 1 _I Partition 2 1 = Enable

I _ 0 _I Partition 2 1 = Enable

  1. = Enable

End Phone with * # + 11 = *# + 12 = # # + 13 = 2.5 second pause

Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

I _ 7 _I Partition 2 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  3. = Monthly

  1. = 6 Hours

  2. = 12 Hours

  3. = 18 Hours

  1. = Enable

1. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif

Hardwire Zones 01 to 08

4219/4229 Zone Expander Zones 10 to 17

Tamper/Trouble Zone 09

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

2. This shows current summary of Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

3. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled 08 = 24 hour Aux/Medical

  1. = Delay Zone 1 09 = Fire

  2. = Delay Zone 2 10 = Interior Delay

  3. = Perimeter/Instant 23 = No Alarm Response

  4. = Interior Follower/Motions 24 = Silent Burglary

  5. = Trouble by Day/Alarm by Night

  6. = 24 hour Silent/Holdup

  7. = 24 hour Police Panic

4. Program Partition of Zone (* for next, # for previous menu)

Tech_201000000093.gif 1 = Partition 1

2 = Partition 2

(Common Zone programming in *81 using Zone List 04)

The common zone will sound and report alarms only if both partitions are armed . When only one partition

is armed, the common zone is automatically treated as if it were a zone type 23 (no alarm response) zone.

A fault on the common zone is displayed in both partitions.

Either partition may arm its system if the common zone is faulted, but once armed, the other partition cannot arm.

That partition must first bypass the common zone or correct the fault before arming.

Either partition can clear and restore the common zone after an alarm.

5. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (Enter 10 in first section if using Contact ID)

7. Enter type of Sensor

Tech_201000000198.gif 2 = AW Auxiliary Wired Zones (Zones 10 and higher)

8. This is the new programming of sensor (* for next, # for previous menu)

Tech_201000000099.gif

9. Normally press 0 to return to start or 1 to enter alpha descriptions

Tech_201000000100.gif

To delete a Zone set Zone Type as 00 then * until "Delete Sensor?", press 1 to delete

I _ 0 _I Partition 2

I _ 0 _I _ 0 _I Partition 2 (1st digit Stay, 2nd Away)

  1. Enter Device to program (01 to 08) (* for next, 00 to exit)

    Tech_201000000101.gif
  1. to 04 are for Output Relays and X-10

05 to 08 X-10 only

2. This shows summary of current Device START programming (* for next, # for previous menu)

Tech_201000000102.gif (What starts the Device)

3. This shows summary of current Device STOP programming (* for next, # for previous menu)

Tech_201000000103.gif (What stops the Device)

4. Enter what Device will do when activated (* for next, # for previous menu)

Tech_201000000104.gif 0 = No Response (or skip)

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Continuous Pulse On/Off

5. Enter what will start the Device (optional) (* for next, # for previous menu)

Tech_201000000105.gif 0 = Not Used (or skip)

  1. = on an Alarm

  2. = on a Zone Fault (or Keyfob button)

  3. = on a Trouble

6. Enter Zone List from *81 which STARTS Device (optional) (* for next, # for previous menu)

Tech_201000000106.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

7. Enter Zone Type that will START the Device (optional) (* for next, # for previous menu)

Tech_201000000107.gif 00 = Not Used (or skip) 24 = Silent Burglary

  1. = Entry/Exit Zone 31 = End of Exit Time

03 = Perimeter/Instant Zone 32 = Start of Entry Time

04 = Interior Follower/Motions 33 = Any Burglar Alarm

05 = Trouble by Day/Alarm by Night 36 = Bell Timeout or Disarm

06 = 24 hour Silent/Holdup 38 = Chime

07 = 24 hour Police Panic 39 = Any Fire Alarm

08 = 24 hour Aux/Medical 40 = Bypassing

09 = Fire 41 = AC Power Failure

10 = Interior Delay 42 = System Low Battery

20 = Arm-Stay 43 = Communication Failure

21 = Arm-Away 52 = Kissoff

22 = Disarming 58 = Duress

8. Enter which Partition will START this Device (Optional) (* for next, # for previous menu)

Tech_201000000108.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

9. Enter Zone List that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000109.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

10. Enter Zone Type that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000110.gif

11. Enter which Partition will STOP this Device (optional) (* for next, # for previous menu)

Tech_201000000111.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

12. This shows summary of new Device START programming (* for next, # for previous menu)

Tech_201000000112.gif

13. This shows summary of new Device STOP programming (* for next, # for previous menu)

Tech_201000000113.gif

14. If this is an X-10 Device enter 1, if not enter 0 (* for next, # for previous menu)

Tech_201000000114.gif

15. Enter next Device to program or 00 to exit

Tech_201000000101.gif

  1. Enter Zone List to program (01 to 04) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif
  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu)

Tech_201000000116.gif Multiple Zones can be added (example: 01* 03* 25*etc)

3. If deleting a Zone List enter (01 to 04) or 0 to skip (* for next, # for previous menu)

Tech_201000000117.gif

  1. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu)

    Tech_201000000118.gif

4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu)

Tech_201000000119.gif Multiple Zones can be deleted (example: 01* 03* 25*etc)

  1. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

  1. = Alarm/Restore

  2. = Trouble/Restore

4 = Bypass/Bypass Restore

8 = Open/Close

  1. = AAV

(Panel MUST be properly grounded for this to work!) 1 = KP Display

2 = KP Display/Sounder

  1. = KP Display/Sounder/Device 2 starts

  1. = Unlimited per Armed period

  1. to 14 = Rings before answer

15 = Answering Machine over-ride