Ademco Vista-20SE/First Alert FA-162C Program Sheet

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (31)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up

  2. Hold 1 & 3 for 3 seconds until flashing " - - 0 0" (if "DA" shows power down then up again)

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 31 then * to exit back to flashing " -- 0 0"

4. Press * to exit

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

I _ 1 _I Partition 2 1 = Enable

  1. = 5800 Wireless

I _ 0 _I _ 0 _I Partition 2 1 = Enable

Partition 2 House Code = Partition 1 House ID + 1 01 to 31

  1. = 4219 8-Zone Expander

  2. = 4229 Zone Expander Module

  3. = 4204 Relay Module

  1. = Enable (Program Zones in Zone List 3)

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

(Allows access to Voice module) 1st digit = 1 to 9

2nd digit = # + 11 = * or # + 12 = #

  1. = Enable

  1. = Enable

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

I _ 6 _I _ 0 _I Partition 2 00 to 99 Seconds

I _ 3 _I _ 0 _I Partition 2 00 to 99 Seconds

I _ 3 _I _ 0 _I Partition 2 00 to 99 Seconds

I _ 1 _I Partition 2 1 = Enable

I _ 0 _I Partition 2 1 = Enable

2 = Enable RF only

  1. = Enable

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

I _ 7 _I Partition 2 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

  6. = All reports except Open/Close Alarms, Open/Close, Troubles

  7. = All reports Alarms, Troubles

  8. = All reports Alarms, Open/Close, Troubles

  9. = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles

  1. = Enable

  1. = 24 Hours

  2. = Weekly

  3. = Monthly

  1. = 6 Hours

  2. = 12 Hours

  3. = 18 Hours

  1. = Sescoa

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Depending on version of system one of these may appear

(If "Program Tool?" press 0, if "Set to Confirm?" shows press 1)

Tech_201000000170.gif Tech_201000000171.gif

2. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif

Hardwire Zones 01 to 08

4219/4229 Zone Expander Zones 10 to 17

Receiver Tamper/Trouble Zone 09

Wireless Zones 10 to 39 (Depends on receiver capacity)

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

3. This shows current summary of Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

4. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled 08 = 24 hour Aux/Medical

  1. = Delay 1 09 = Fire

  2. = Delay 2 10 = Interior Delay

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

  6. = 24 hour Silent/Holdup 23 = No Alarm Response

  7. = 24 hour Police Panic 24 = Silent Burglary

4a. Enter only if Hardwire Zone (* for next, # for previous menu)

Tech_201000000189.gif 0 = 10msec

1 = 350msec

2 = 700msec

5. Program Partition of Zone (* for next, # for previous menu)

Tech_201000000093.gif 1 = Partition 1

2 = Partition 2

6. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (10 in first section gives a report of A0)

Hardwire Zones will advance to step 11, for Wireless Zones continue

7. Enter type of Sensor

Tech_201000000095.gif 2 = Auxiliary Wired Sensor (if 4219/4229 Zone Expander)

3 = Supervised RF (most sensors are RF)

4 = Un-Supervised RF

5 = RF Button Type (Keyfobs/Panics etc)

8. Enter Loop number (* for next, # for previous menu)

Tech_201000000096.gif

Door Switch Internal switch Loop 2, external hardwire sensor Loop 1

Glassbreak Loop 1

Smoke Detectors Loop 1

Motions Loop 1

Keyfobs Bottom Right Button = Loop 1

(Each button counts as 1 zone) Top Right Button = Loop 2

Top Left Button = Loop 3

Bottom Left Button = Loop 4

9. Serial Number Programming (* for next, # for previous menu)

Tech_201000000172.gif

Enter serial number or trip sensor twice, Loop number will also be learned

Note: Serial numbers found on sticker on of sensor, if not, learn by tripping sensor

Tech_201000000173.gif This shows ready to learn

Tech_201000000174.gif This shows Serial Number either manually entered or learned

Tech_201000000175.gif This shows sensor was confirmed by activating twice

10. If "Set to Confirm" was selected while first entering *56 this will appear

Tech_201000000191.gif Trip sensor again to confirm

If incorrect serial number was learned this will appear

Tech_201000000192.gif

(This can be used to find out a serial number if sticker was removed)

11. This is the new programming of sensor (* for next, # for previous menu)

Tech_201000000099.gif

12. 0 or * returns to beginning, 1 programs alpha descriptors

Tech_201000000100.gif

To delete a Zone set Zone Type as 00 then * until "Delete Sensor?", press 1 to delete

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) then *

Tech_201000000176.gif

3. Enter Zone Type (Display moves to Report Code, # starts over)

Tech_201000000177.gif 00 = Zone Disabled 08 = 24 hour Aux/Medical

  1. = Delay Zone 09 = Fire

  2. = Do not Use 10 = Interior Delay

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

  6. = 24 hour Silent/Holdup 23 = No Alarm Response

  7. = 24 hour Police Panic 24 = Silent Burglary

4. Display moves to Report Code, if needed enter 10 (Display moves to Sensor Type, # starts over)

Tech_201000000178.gif

A key moves left through fields if needed

B key moves right through fields if needed

C key copies previous Zone attributes

Hardwired Zones automatically skip to step 9, Wireless Zones continue with step 5

5. Enter Wireless sensor type then *

Tech_201000000179.gif 3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

6. If Wireless enter Serial Number or trip sensor twice (Keypad will beep twice as Sensor learns)

Tech_201000000180.gif

Tech_201000000181.gif

7. Enter Loop only if manually entering Serial Number (* for next, # for previous menu)

Tech_201000000182.gif

8. If "Set to Confirm" was selected while first entering *58 this will appear

Tech_201000000183.gif Trip sensor again to confirm

Tech_201000000184.gif This shows panel and sensor serials match

9. Enter next sensor or 00 then * or # to exit *58 menu

Tech_201000000185.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

I _ 0 _I Partition 2

I _ 0 _I _ 0 _I Partition 2 (1st digit Stay, 2nd Away)

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Device to program (01 to 08) (* for next, 00 to exit)

    Tech_201000000101.gif
  1. to 02 for 4229 Relay/Zone Expander

  1. to 04 for 4204 Relay Module

  1. to 08 for X-10

  2. This shows summary of current Device START programming (* for next, # for previous menu)

    Tech_201000000102.gif
(What starts the Device)

  1. This shows summary of current Device STOP programming (* for next, # for previous menu)

    Tech_201000000103.gif
(What stops the Device)

  1. Enter what Device will do when activated (* for next, # for previous menu)

    Tech_201000000104.gif
0 = No Response (or skip)

  1. = Close for 2 seconds

  2. = Close and stay closed

  3. = Continuous Pulse On/Off

5. Enter what will start the Device (optional) (* for next, # for previous menu)

Tech_201000000105.gif 0 = Not Used (or skip)

  1. = on an Alarm

  2. = on a Zone Fault (or Keyfob button)

  3. = on a Trouble

6. Enter Zone List from *81 which STARTS Device (optional) (* for next, # for previous menu)

Tech_201000000106.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

7. Enter Zone Type that will START the Device (optional) (* for next, # for previous menu)

Tech_201000000107.gif 00 = Not Used (or skip) 24 = Silent Burglary

  1. = Entry/Exit Zone 31 = End of Exit Time

03 = Perimeter/Instant Zone 32 = Start of Entry Time

04 = Interior Follower/Motions 33 = Any Burglar Alarm

05 = Trouble by Day/Alarm by Night 36 = Bell Timeout or Disarm

06 = 24 hour Silent/Holdup 38 = Chime

07 = 24 hour Police Panic 39 = Any Fire Alarm

08 = 24 hour Aux/Medical 40 = Bypassing

09 = Fire 41 = AC Power Failure

10 = Interior Delay 42 = System Low Battery

20 = Arm-Stay 43 = Communication Failure

21 = Arm-Away 52 = Kissoff

22 = Disarming 58 = Duress

8. Enter which Partition will START this Device (Optional) (* for next, # for previous menu)

Tech_201000000108.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

9. Enter Zone List that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000109.gif 0 = Not Used (or skip)

  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3

10. Enter Zone Type that will STOP the Device (optional) (* for next, # for previous menu)

Tech_201000000110.gif

11. Enter which Partition will STOP this Device (optional) (* for next, # for previous menu)

Tech_201000000111.gif 0 = Any Partition

  1. = Partition 1

  2. = Partition 2

12. This shows summary of new Device START programming (* for next, # for previous menu)

Tech_201000000112.gif

13. This shows summary of new Device STOP programming (* for next, # for previous menu)

Tech_201000000113.gif

14. If this is an X-10 Device enter 1, if not enter 0 (* for next, # for previous menu)

Tech_201000000114.gif

15. Enter next Device to program or 00 to exit

Tech_201000000101.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. Enter Zone List to program (01 to 04) or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif
  1. = Zone List 1

  2. = Zone List 2

  3. = Zone List 3 and Chime Zones

  4. = Zone List 4 (Common Lobby Zones)

2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu)

Tech_201000000116.gif Multiple Zones can be added (example: 01* 03* 25*etc)

3. If deleting a Zone List enter (01 to 04) or 0 to skip (* for next, # for previous menu)

Tech_201000000117.gif

4. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu)

Tech_201000000118.gif

4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu)

Tech_201000000119.gif Multiple Zones can be deleted (example: 01* 03* 25*etc)

  1. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

    Tech_201000000115.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. = Alarm/Restore

  2. = Trouble/Restore

4 = Bypass/Bypass Restore

8 = Open/Close

F (#15) All Options Enabled

  1. = AAV 2-way module enabled

(4 disables siren during 2-way)

  1. = KP Display

  2. = KP Display/Sounder

  3. = KP Display/Sounder/Device 2 starts

  1. = Unlimited per Armed period

  1. to 14 = Rings before answer

15 = Answering Machine over-ride