Ademco Vista-50P Program Sheet

Wireless Info Vista-50P v6 and below support 5700 and 5800 series wireless

Vista-50P v8 and above support 5800 series wireless

Enter Program 1. 4140 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97, answer YES if using alpha keypads

Compatibility

Power Ratings 750ma Aux output

  1. 7A Siren output

Device Address All keypads, receivers and expanders must be addressed and added in #93 menu

Address 00 to 03 are pre-programmed as alpha keypads

Address first keypad as 00 to allow entry into programming

00 Alpha Keypad (cannot be changed)

  1. to 30 Keypads, zone expanders, wireless receivers etc

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (00 to 30)

  4. Press * to save and exit

(6128RF/6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0 "

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Enter new address (00 to 30) then * to exit back to flashing " -- 0 0 "

  5. Press * to exit

Partition Stuff (If system is partitioned)

  1. Press *91

  2. Enter Partition (1 to 8)

  3. Enter location (all locations on this page marked (Partition Specific))

  4. Press *99 to return to regular panel programming

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

All Zone programming is done by # 93 menu, enter #93 for below menu (Click to go to section)

Tech_201000000129.gif 1 enters, 0 moves to next menu (Expert Mode Programming)

Tech_201000000480.gif 1 enters, 0 moves to next menu (Serial Zone Programming)

Tech_201000000492.gif 1 enters, 0 moves to next menu (Alpha Zone Programming)

Tech_201000000130.gif 1 enters, 0 moves to next menu (Device Programming)

Tech_201000000131.gif 1 enters, 0 moves to next menu (Relay Programming)

Tech_201000000225.gif 1 enters, 0 moves to next menu (Relay/Voice Descriptors)

Tech_201000000226.gif 1 enters, 0 moves to next menu (Custom Index)

Tech_201000000227.gif 1 enters, 0 moves to next screen

Tech_201000000132.gif 1 exits #93 menu, 0 moves back to Zone Program

(Partition Specific)

(Partition Specific)

(Partition Specific)

(Partition Specific)

(Partition Specific)

  1. = 10 ms

  1. to 8 = Partition 1 to 8

(Partition Specific) 1 = 1/2 second siren at end of Exit Delay

or Kissoff if sending closing reports

  1. = Keypad sounds 2-minutes after AC loss

  1. = Siren sounds 4 hours after AC loss

  1. = Randomize 10 - 40 Minutes after AC loss

  1. nd Digit = 11 (*) or 12 (#)

  1. = No Timeout

(Partition Specific) I _1 _I 96 3 & # 1 = Enable

I _1 _I 99 * & #

(Partition Specific) 1 = More than 1 Alarm per Arming Period

  1. = Ignore Tampers from RF, RPM Expansion Modules

  1. = Trigger Voltage to Pin 7 of J7 Header

  1. = No Test report if any other report was recently sent

  1. to 999 Hours

  1. = Enable

(Partition Specific) 1 = # + 2 = Away Arm

# + 3 = Stay Arm

# + 4 = Maximum Arm

# + 7 = Instant Arm

  1. = Touch Tone

(Example 9 is 09*)

(Example 1234 is 01 02 03 04) Hex B = 11 C = 12 D = 13 E = 14 F = 15

(17 digits, end with *) # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(15's Default CSID to Factory)

I _1 _I Sys Shutdown 1 = Enable

I _0 _I Not Used

I _1 _I Remote Bypass

I _1 _I Remote Disarm

I _1 _I Remote Arm

I _1 _I Upload Enable

I _1 _I Download Enable

(Partition Specific) 01 to 86 Zone that cannot be bypassed

(Partition Specific) 1 = Disable

  1. = Enable

  1. = Zones 2 to 8 Normally Closed Loops

  1. = 11 seconds

  2. = 30 seconds

  1. = Wait for true dial tone

  1. to 14 = Rings to Answer

15 = Answering Machine Over-Ride

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

  1. = Contact ID

  2. = Ademco High Speed

  3. = Ademco Express

  1. = Sescoa/Radionics

I _0 _I Secondary 1 = Enable

  1. = Radionics

  1. = All Reports to Primary and Secondary Numbers

I _0 _I Restore 1 = Expanded

I _0 _I Bypass

I _0 _I Trouble

I _0 _I Open/Close

I _0 _I Low Battery

I _0 _I Restore 1 = Expanded

I _0 _I Bypass

I _0 _I Trouble

I _0 _I Open/Close

I _0 _I Low Battery

I _0 _I Zone Type 2 1 = Enable

I _0 _I Zone Type 3

I _0 _I Zone Type 4

I _0 _I Zone Type 5

I _0 _I Zone Type 6

I _0 _I Zone Type 7

I _0 _I Zone Type 8

I _0 _I Zone Type 10 1 = Enable

I _0 _I _0 _I Close I _0 _I _0 _I Close

I _0 _I _0 _I Open I _0 _I _0 _I Open

I _1 _I _1 _I Low Battery I _0 _I _0 _I Low Battery

I _0 _I _0 _I Low Battery Restore I _0 _I _0 _I Low Battery Rest

I _1 _I _1 _I AC Loss I _0 _I _0 _I AC Loss

I _0 _I _0 _I AC Loss Restore I _0 _I _0 _I AC Loss Rest

I _0 _I _0 _I Test I _0 _I _0 _I Test

I _0 _I _0 _I Power I _0 _I _0 _I Power

I _1 _I _1 _I Cancel I _0 _I _0 _I Cancel

I _0 _I _0 _I Program Tamper I _0 _I _0 _I Program Tamper

I _1 _I _2 _I Hours 00 to 23

I _0 _I _0 _I Minutes 00 to 59

(Partition Specific) 01 to 15 Alarms

(Partition Specific) I _1 _I Zone 96 (3 & #) 1 = Enable

I _1 _I Zone 99 (* & #)

I _1 _I Zone 92 (Duress)

(Partition Specific) 1 = Continuous during Entry Delay

(Partition Specific) 1 = 16 Seconds

  1. = At Bell Timeout

  2. = At Disarm

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 2nd Level of Programming press *94 then enter * + 2-digits, to exit back to 1st Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *17 Common Lobby I _0 _I 0 = Disable

  1. to 8 = Partition 1 to 8

  1. *18 Affects Lobby I _0 _I 0 = Does not affect Common Lobby

(Partition Specific) 1 = Affects Common Lobby

  1. *19 Arms Lobby I _0 _I 0 = Does not Arm Common Lobby

(Partition Specific) 1 = Arms Common Lobby

  1. *20 Exit Error Logic I _0 _I 0 = Disable

  1. = Bypas Faulted Zones after Arming

  1. *21 Exit Delay Reset I _0 _I 0 = Disable

  1. = Reset Delay 60 seconds after Zone Closes

  1. *28 RF Low Battery Sound I _0 _I 0 = When Disarmed

  1. = Immediate

  1. *29 RF Low Battery Report Enable I _0 _I 0 = Disable

  1. = Enable

  1. *30 RF RCVR Check-IN Interval I _0 _I _6 _I 00 = Supervision Disabled

  2. to 15x2 Hours

  1. *31 RF Transmitter Check in Interval I _1 _I _2 _I 00 = Supervision Disabled

  2. to 15x2 Hours

  1. *32 RF Receiver Type I _0 _I 0 = Disabled

Vista-50P v1 to v6 support 5700 and 5800 series wireless 1 = 4281 (5700 series wireless)

Vista-50P v8 and above supports 5800 series wireless 2 = 5881 (5800 series wireless)

  1. *33 Touch-Tone with Rotary Backup I _0 _I 0 = Disable

  1. = Rotary dial if 1st Touch-Tone dial attempt fails

  1. *34 Communication Split Report Selection I _0 _I 0 = Disable

  1. = Alarms Primary, others Secondary

  2. = Open/Close & Test Secondary, others Primary

  1. *40 Non-Alarm Dialer Codes 1st Digit 1*41 Non-Alarm Dialer Codes 2nd Digit

I _0 _I _0 _I Armed Stay I _0 _I _0 _I Armed Stay

I _0 _I _0 _I Time Set/Event Log Reset I _0 _I _0 _I Time Set/Event Log Reset

I _0 _I _0 _I Event Log 50% & 90% Full I _0 _I _0 _I Event Log 50% & 90% Full

I _0 _I _0 _I Event Log Overflow I _0 _I _0 _I Event Log Overflow

I _0 _I _0 _I Exit Error (Zone) I _0 _I _0 _I Exit Error (Zone)

I _0 _I _0 _I Exit Error (User) I _0 _I _0 _I Exit Error (User)

I _0 _I _0 _I Recent Close I _0 _I _0 _I Recent Close

  1. *42 Call Waiting Defeat I _0 _I 0 = Disable

  1. = Enable

  1. *43 Perm Keypad Backlight I _0 _I 0 = Disable

(Partition Specific) 1 = Enable

  1. *45 Exit Delay Sounder I _0 _I 1 = Enable

(Partition Specific) 0 = Disable

  1. *48 Wireless Keypad Assignment I _0 _I 0 = Disable

  1. to 8 = Partition 1 to 8

  1. *49 Suppress TX Supervision Sound I _1 _I 0 = Enable

  1. = Disable

  1. *52 Send Cancel If Alarm + Off I _0 _I 0 = Within Bell Timeout

(Partition Specific) 1 = No Restriction

  1. *53 Download Callback Enable I _1 _I 0 = Callback Required

  1. = No Callback Required

  1. *57 Enable 5800 RF Button Global Arm I _0 _I 0 = Keyfob will not Global Arm

  1. = Follows Global User Settings

  1. *58 Enable 5800 RF Button Force Bypass I _0 _I 0 = Disable

  1. = Enable

  1. *59 VIM Audio Callback ID I _ _I _ _I _ _I _ _I 4-Digits

  1. *60 Zone 5 Audio Verification I _1 _I 0 = Disable

(Do not use Zone 5 if this option is enabled) 1 = Enable

  1. *70 Event Log Types I _1 _I Alarm 0 = Disable Logging

I _0 _I Check 1 = Enable Logging

I _0 _I Bypass

I _0 _I Open/Close

I _1 _I System

  1. *71 12/24 Hour Time Stamp Format I _0 _I 0 = 12 Hour

  1. = 24 Hour (Military)

  1. *72 Event Log Printer On-Line I _0 _I 0 = Disable

  1. = Enable

1*73 Event Log Printer Baud Rate I _0 _I 0 = 1200 Baud

  1. = 300 Baud

  1. *74 Relay Timeout Minutes I _0 _I _0 _I _0 _I 0 to 127 x2 minutes

  1. *75 Relay Timeout Seconds I _0 _I _0 _I _0 _I 0 to 127 seconds

  1. *76 Access Control Relay for Partition I _0 _I _0 _I 00 = None

(Partition Specific) 01 to 16 = Relay used when Code + 0

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 3rd Level of Programming press *94 then enter * + 2-digits, to exit back to 2nd Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *00 Number of Partitions I _1 _I 1 to 8 = Partition 1 to 8

2*01 Daylight Savings Time I _0 _I _4 _I Start 00 = January to 12 = December

Start/End Month I _1 _I _0 _I End

2*02 Daylight Savings Time I _1 _I Start 1 = 1st Weekend

Start/End Weekend I _5 _I End 2 = 2nd Weekend

  1. = 3rd Weekend

  2. = 4th Weekend

  3. = Last Weekend

  4. = Next to Last Weekend

  5. = 3rd from Last Weekend

2*05 Auto-Arm Delay I _1 _I _5 _I 15 = Auto-Arm Disabled

(Partition Specific) 01 to 14 x4 Minutes

2*06 Auto-Arm Warning Period I _0 _I _0 _I 00 = Instant at end of Arming Delay

(Partition Specific) 01 to 15 Minutes

2*07 Auto-Disarm Delay I _1 _I _5 _I 00 = Instant at end of Window

(Partition Specific) 15 = No Auto-Disarm

  1. to 14 x4 Minutes

  2. *08 Enable Force Arm for Auto-Arm I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*09 Open/Close Reports by Exception I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*10 Allow Disarm only during I _1 _I 0 = Disable

Arm/Disarm Window 1 = Enable

(Partition Specific)

2*11 Allow Disarm Outside Window I _1 _I 0 = Disable

If Alarm Occurs 1 = Enable

(Partition Specific)

2*13 Schedule Related Report Codes 1st Digit 2*14 Schedule Related Report Codes 2nd Digit

I _0 _I _0 _I Early Opening Report Code I _0 _I _0 _I Early Opening Report Code

I _0 _I _0 _I Early Closing Report Code I _0 _I _0 _I Early Closing Report Code

I _1 _I _1 _I Late Opening Report Code I _0 _I _0 _I Late Opening Report Code

I _0 _I _0 _I Late Closing Report Code I _0 _I _0 _I Late Closing Report Code

I _1 _I _1 _I No Opening (Late to Open) Report Code I _0 _I _0 _I No Opening (Late to Open) Report Code

I _0 _I _0 _I No Closing (Late to Close) Report Code I _0 _I _0 _I No Closing (Late to Close) Report Code

I _0 _I _0 _I Auto Arm Failure Report Code I _0 _I _0 _I Auto Arm Failure Report Code

I _0 _I _0 _I Access Schedule Changed Report Code I _0 _I _0 _I Access Schedule Changed Report Code

2*18 Enable Goto For This Partition I _1 _I 0 = Disable

(Partition Specific) 1 = Enable

2*19 Use Partition Descriptors I _1 _I 0 = Disable

  1. = Display Partition Number and 4-digit Descriptor

  2. *20 Enable J7 Triggers by Partition I _1 _I 0 = Disable for displayed Partition

(Partition Specific) 1 = Enable for displayed Partition

2*21 Enable Supervision Pulses for I _0 _I Fire 0 = Disable

Long Range Radio Trigger Outputs I _0 _I Burglary 1 = Enable

I _0 _I Silent Panic/

Duress