Ademco Vista-XM/First Alert FA1000C Program Sheet

Enter Program 1. 4140 or 5140 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97, answer YES if using alpha keypads

Compatibility

Go-No Go Test (Verifies adequate RF by reducing RF receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Send to 1. Exit programming

Downloader 2. Press Installer or Master Code + # + 1

3. "CC" or "MODEM COMM" appears for approx. 2 minutes

4. Display will return to normal once upload is finished

Hex Program Hex A = 10 B = 11 C = 12 D = 13 E = 14 F = 15

Alpha Keypads can only be 5330 or 5337, cannot use 6139 (NOT required for programming)

l__?__l__?__l Zone 1 l__?__l__?__l Zone 9 00 = Disabled

l__?__l__?__l Zone 2 l__?__l__?__l Zone 10 01 = Entry/Exit 1

l__?__l__?__l Zone 3 l__?__l__?__l Zone 11 02 = Entry/Exit 2

l__?__l__?__l Zone 4 l__?__l__?__l Zone 12 03 = Instant

l__?__l__?__l Zone 5 l__?__l__?__l Zone 13 04 = Interior

l__?__l__?__l Zone 6 l__?__l__?__l Zone 14 05 = Day Zone

l__?__l__?__l Zone 7 l__?__l__?__l Zone 15 06 = Holdup

l__?__l__?__l Zone 8 l__?__l__?__l Zone 16 07 = Police

08 = Medical

l__?__l__?__l Zone 17 l__0__l__0__l Not Used 10 = InteriorDelay

l__0__l__0__l Not Used l__0__l__0__l Not Used

l__0__l__0__l Not Used l__0__l__0__l Not Used

l__0__l__0__l Not Used l__0__l__0__l Not Used

l__0__l__0__l Not Used l__0__l__0__l Polling Loop Short

l__0__l__0__l Not Used l__0__l__8__l 1 & * / A Panic Key (Keypad Medical)

l__0__l__0__l Not Used l__0__l__9__l 3 & # / C Panic Key (Keypad Fire)

l__0__l__0__l Not Used l__0__l__7__l * & # / B Panic Key (Keypad Police)

10 11 12 13 14 15 16 1 = 4190WH or aux loop on 4196

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

  1. = Enable

  1. = Enable

  1. = Enable

  1. = Disables Internal Sounder (4130XM/5130XM)

  1. = Enable

  1. = Enable

  1. = Multiple Alarms per arming period

  1. = Enable

  1. = Enable

  1. = Steady

  1. = 12 Hours

  2. = 24 Hours

  3. = 168 Hours

  1. = Enable

  1. = Enable

  1. = Touch-Tone Dial

(Example 9 is 09* )

(Example 1234 is 01 02 03 04) Hex B = 11 C = 12 D = 13 E = 14 F = 15

(12 digits, end with * ) # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(15's Default CSID to Factory)

I _1 _I System Shutdown 1 = Enable

I _0 _I Not Used

I _1 _I Remote Bypass

I _1 _I Remote Disarm

I _1 _I Remote Arm

I _1 _I Upload Programming

I _1 _I Download Programming

  1. to 64 Zone that cannot be bypassed

  1. = Normally Closed

  1. = 11 seconds

  2. = 30 seconds

  1. = Enable

  1. to 14 = Rings before Answer

15 = Answering Machine

  1. = 60 seconds

(See 1*32 to enable Contact ID) 1 = Sescoa/Radionics

2 = Hi Speed

  1. = 60 seconds

(See 1*32 to enable Contact ID) 1 = Sescoa/Radionics

2 = Hi Speed

  1. = Enable

  1. = Sescoa

  1. = Enable

(User 1 must be 1 to allow Installer entry into programming) 1 = Enable

  1. = Enable

  1. = 4/2 Reporting

  1. = Expanded

  1. = Expanded

  1. = Expanded

  1. = Expanded

  1. = Expanded

  1. = Expanded

This reporting is set for Contact ID, many locations are missing and are not required for this format

I _0 I _1 _I Zone 1 I _0 I _9 _I Zone 9

I _0 I _2 _I Zone 2 I _0 I _1 _I Zone 10

I _0 I _3 _I Zone 3 I _0 I _2 _I Zone 11

I _0 I _4 _I Zone 4 I _0 I _3 _I Zone 12

I _0 I _5 _I Zone 5 I _0 I _4 _I Zone 13

I _0 I _6 _I Zone 6 I _0 I _5 _I Zone 14

I _0 I _7 _I Zone 7 I _0 I _6 _I Zone 15

I _0 I _8 _I Zone 8 I _0 I _7 _I Zone 16

I _0 I _8 _I Zone 17 I _0 I _7 _I Zone 25

I _0 I _9 _I Zone 18 I _0 I _8 _I Zone 26

I _0 I _1 _I Zone 19 I _0 I _9 _I Zone 27

I _0 I _2 _I Zone 20 I _0 I _1 _I Zone 92 (Duress)

I _0 I _3 _I Zone 21 I _0 I _0 _I Zone 97 (Polling Loop Short)

I _0 I _4 _I Zone 22 I _0 I _2 _I Zone 95 ( 1 & * Medical Panic)

I _0 I _5 _I Zone 23 I _0 I _3 _I Zone 96 (3 & # Fire Panic)

I _0 I _6 _I Zone 24 I _0 I _4 _I Zone 99 (* & # Police Panic)

I _0 I _1 _I Channel 1 I _0 I _9 _I Channel 9

I _0 I _2 _I Channel 2 I _1 I _0 _I Channel 10

I _0 I _3 _I Channel 3 I _1 I _1 _I Channel 11

I _0 I _4 _I Channel 4 I _1 I _2 _I Channel 12

I _0 I _5 _I Channel 5 I _1 I _3 _I Channel 13

I _0 I _6 _I Channel 6 I _1 I _4 _I Channel 14

I _0 I _7 _I Channel 7 I _1 I _5 _I Channel 15

I _0 I _8 _I Channel 8 I _0 I _0 _I Not Used

I _0 I _1 _I AC Loss I _0 I _0 _I Open

I _0 I _0 _I AC Loss 2nd Digit I _0 I _0 _I Close

I _0 I _1 _I Trouble I _0 I _1 _I Low Battery

I _0 I _1 _I Trouble Restore I _0 I _0 _I Low Battery 2nd Digit

I _0 I _0 _I Bypass I _0 I _0 _I Test

I _0 I _0 _I Bypass Restore I _0 I _0 _I Power Up

I _0 I _1 _I Alarm, AC, Low Bat Restore I _0 I _0 _I Not Used

I _0 I _1 _I Cancel

I _0 I Zone Type 1 0 = No

I _0 I Zone Type 2 1 = Yes

I _0 I Zone Type 3

I _0 I Zone Type 4

I _0 _I Zone Type 5 0 = No

I _0 _I Zone Type 6 1 = Yes

I _0 _I Zone Type 7

I _0 _I Zone Type 8

I _0 I Zone Type 9 0 = No

I _0 I Zone Type 10 1 = Yes

  1. to 14 Rings before Answer

15 = Double Call Enable

  1. 31 hrs

  1. = Watts Line

  1. = 4206

  1. = Continuous

  1. = 16 seconds

  1. = Alarm Trig, No Zone Exp

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

To access 2nd Level of Programming press *94 then enter * + 2-digits, to exit back to 1st Level Programming enter *99

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------

  1. *00 Open/Close Rep Users 17 to 22 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I 0 = Disable

  1. = Enable

  1. *01 Zone Types for Zones 28 to 32 1*02 Zone Types for Zones 22 to 40

I _? _I _? _I Zone 28 I _? _I _? _I Zone 33 00 = Disabled

I _? _I _? _I Zone 29 I _? _I _? _I Zone 34 01 = Entry/Exit 1

I _? _I _? _I Zone 30 I _? _I _? _I Zone 35 02 = Entry/Exit 2

I _? _I _? _I Zone 31 I _? _I _? _I Zone 36 03 = Instant

I _? _I _? _I Zone 32 I _? _I _? _I Zone 37 04 = Interior

I _? _I _? _I Zone 38 05 = Day Zone

I _? _I _? _I Zone 39 06 = Holdup

I _? _I _? _I Zone 40 07 = Police

08 = Medical

  1. *03 Zone Types for Zones 41 to 48 1*04 Zone Types for Zones 49 to 56 09 = Fire

I _? _I _? _I Zone 41 I _? _I _? _I Zone 49 10 = Interior Delay

I _? _I _? _I Zone 42 I _? _I _? _I Zone 50

I _? _I _? _I Zone 43 I _? _I _? _I Zone 51

I _? _I _? _I Zone 44 I _? _I _? _I Zone 52

I _? _I _? _I Zone 45 I _? _I _? _I Zone 53

I _? _I _? _I Zone 46 I _? _I _? _I Zone 54

I _? _I _? _I Zone 47 I _? _I _? _I Zone 55

I _? _I _? _I Zone 48 I _? _I _? _I Zone 56

  1. *05 Zone Types for Zones 57 to 64

I _? _I _? _I Zone 57

I _? _I _? _I Zone 58

I _? _I _? _I Zone 59

I _? _I _? _I Zone 60

I _? _I _? _I Zone 61

I _? _I _? _I Zone 62

I _? _I _? _I Zone 63

I _? _I _? _I Zone 64

  1. *06 Not Used

  1. *07 Not Used

  1. *08 Assign Response Type for 2nd 4280 1*09 1st & 2nd Receiver Troubles

I _0 _I _0 _I Not Used I _0 _I _0 _I Zone 89 2nd Receiver

I _0 _I _0 _I Not Used I _0 _I _0 _I Zone 90 1st Receiver

I _0 _I _0 _I Not Used I _0 _I _0 _I Zone 91 1st Receiver

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 88 2nd Receiver

  1. *10 Right Loop Zones 33 to 40 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I 0 = Disable

  1. *11 Right Loop Zones 41 to 48 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I 1 = Enable

  1. *12 Right Loop Zones 49 to 56 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *13 Right Loop Zones 57 to 64 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *14 to 1*17 Not Used

  1. *18 Enable Wireless Zones 1 to 8 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I 0 = Disable

  1. *19 Enable Wireless Zones 9 to 16 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I 1 = Enable

  1. *20 Enable Wireless Zones 17 to 24 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *21 Enable Wireless Zones 25 to 32 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *22 Enable Wireless Zones 33 to 40 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *23 Enable Wireless Zones 41 to 48 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *24 Enable Wireless Zones 49 to 56 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *25 Enable Wireless Zones 57 to 63 I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I _0 _I

  1. *26 First 4280 RF Receiver Select I _0 _I 0 = Disable

  1. = Enable

  1. *27 Second 4280 RF Receiver Select I _0 _I 0 = Disable

  1. = Enable

  1. *28 RF Low Battery Sound I _0 _I 0 = Disarmed

  1. = Immediate

  1. *29 RF Low Battery Report Enable I _1 _I 0 = Disable

  1. = Enable

  1. *30 RF RCVR Check-IN Interval I _0 _I _6 _I 00 = Disable, 02 to 15 x2 Hrs

  1. *31 RF Transmitter Check in Interval I _1 _I _2 _I 00 = Disable, 02 to 15x2 Hrs

  1. *32 Ademco H.S Contact ID Rep Fmt I _1 _I 0 = Standard Hi Speed

  1. = Contact ID Format

  1. *33 Touch-Tone with Rotary Backup I _1 _I 0 = Disable

  1. = Enable

  1. *34 Comm Split Report Selection I _1 _I 0 = No

  1. = Alarms Primary

  2. = O/C Secondary

  1. *35 Channel Assigned to Zones 28 to 32 1*36 Channel Assigned to Zones 33 to 40

I _0 I _1 _I Zone 28 I _0 I _9 _I Zone 33

I _0 I _2 _I Zone 29 I _0 I _1 _I Zone 34

I _0 I _3 _I Zone 30 I _0 I _2 _I Zone 35

I _0 I _4 _I Zone 31 I _0 I _3 _I Zone 36

I _0 I _5 _I Zone 32 I _0 I _4 _I Zone 37

I _0 I _5 _I Zone 38

I _0 I _6 _I Zone 39

I _0 I _7 _I Zone 40

  1. *37 Channel Assigned to Zones 41 to 48 1*38 Channel Assigned to Zones 49 to 56

I _0 I _8 _I Zone 41 I _0 I _7 _I Zone 49

I _0 I _9 _I Zone 42 I _0 I _8 _I Zone 50

I _0 I _1 _I Zone 43 I _0 I _9 _I Zone 51

I _0 I _2 _I Zone 44 I _0 I _1 _I Zone 52

I _0 I _3 _I Zone 45 I _0 I _0 _I Zone 53

I _0 I _4 _I Zone 46 I _0 I _2 _I Zone 54

I _0 I _5 _I Zone 47 I _0 I _3 _I Zone 55

I _0 I _6 _I Zone 48 I _0 I _4 _I Zone 56

  1. *39 Channel Assigned to Zones 57 to 64

I _0 I _1 _I Zone 57

I _0 I _2 _I Zone 58

I _0 I _3 _I Zone 59

I _0 I _4 _I Zone 60

I _0 I _5 _I Zone 61

I _0 I _6 _I Zone 62

I _0 I _7 _I Zone 63

I _0 I _8 _I Zone 64

  1. *40 Armed Stay Report 1st Digit

I _0 _I _0 _I

  1. *41 Armed Stay Report 2nd Digit

I _0 _I _0 _I

  1. *08 Assign Response Type for 2nd 4280

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Not Used

I _0 _I _0 _I Zone 88 2nd Receiver

  1. *09 1st & 2nd Receiver Troubles

I _0 _I _0 _I Zone 89 2nd Receiver

I _0 _I _0 _I Zone 90 1st Receiver

I _0 _I _0 _I Zone 91 1st Receiver

  1. *44 RF Keypad Tamper Detect I _0 _I 0 = Disable

  1. = Enable

  1. *45 Enable Exit Beeps I _1 _I 0 = Disable

  1. = Enable

  1. *46 Aux Output Enable I _0 _I 0 = Ground Start

  1. = O/C Trigger

  2. = Console Sound

  1. *47 Chime on External Sounder I _0 _I 0 = Disable

  1. = Enable

  1. *48 Wireless Keypad Disable I _0 _I 0 = Disable

  1. = Enable

  1. *49 Suppress Trouble Sound for RF I _1 _I 0 = Disable

  1. = Enable

  1. *50 Babysitter Code User 22 I _1 _I 0 = Disable

  1. = Enable

  1. *52 Send Cancel if Alarm + Off I _0 _I 1 = None

0 = Timeout