Radionics D2212/D2412/D2812 Program Sheet Click HERE for D5200 Programmer

Power Ratings 1A Aux output

  1. 85A Siren output

Formats Modem IIIa2, 4x2

Download Info Answering Machine bypass must be ON

  1. Call panel with standard phone, wait for one or two rings, hangup and wait 30 seconds

  2. Call panel with standard phone, wait for one or two rings, hangup and wait 30 seconds

  3. Call panel with downloader, panel should pick up

or

Press 2 + User or Installer Passcode

Program Info Program requires any of the following

  1. D5200 Programmer (Use D2212 Product Handler)

  2. RAM II or RAM IV download software

  3. Text Keypad set at address 1 (D222 or D223)

(D202A and D220A LED Keypads will not work

Enter Program 1. Clip Standby switch on main board

2. Press 1, keypad should beep

3. Enter Installer Code (Default=654321, if Protect America use 1010)

(If Customer uses a 4-digit Code then Installer Code is only 4-digits)

  1. Press 8 to enter program mode

Exit Program Press CLEAR key, all Zone lights except 4 will turn ON, unclip Standby Switch

(System will now send a Reboot (R14) signal)

Program Keys A Key moves from View Data Mode to Modify Data Mode

(View Mode) B Key moves to previous Group (1 to 14)

C Key moves to next Group (1 to 14)

CLEAR Key exits keypad programming (Unhook Program Latch to completely exit)

Program Keys A Key moves from View Data Mode to Modify Data Mode

(Modify Mode) B Key scrolls backwards through list of options, Press for YES/NO toggling

C Key scrolls forward through list of options and characters

CLEAR Key exits Modify Data Mode and goes back to View Data Mode

0 to 9 used for Phone/Account/Report Codes etc

Hex Program While modifying a Location C+2=A, C+3=B, C+4=C, C+5=D, C+6=E, C+7=F

4/2 Signals CLICK HERE FOR LIST OF WHAT BELOW PROGRAMMING WILL REPORT

  1. System Configuration Underlined = Default

  1. Account Number (4-digits) 0 to 9 / B to F

  2. Swinger Count 3 1 = 1 Alarm before bypass

2 = 2 Alarms before bypass

  1. = 3 Alarms before bypass

  2. = 4 Alarms before bypass

3 Keyswitch 0 0 = Momentary

  1. = Easikey

4 Custom Idle Text RADIONICS 1st line of LCD keypad display

5 Custom Idle Text D2212 2nd line of LCD keypad display

6 Custom Service Text (Blank) Displays only during system troubles

  1. Phone Underlined = Default

  1. DTMF Dialing 1 = Yes 0 = No

  1. = Yes

  2. Phone 1 (19 digits) 0 to 9 / # / *

C = 3 second pause

  1. Phone 2 (Leave Blank) D = 7 second dial tone wait

  2. Phone Routing 1 = Yes 0 = No

  1. = Yes

(Yes enables below routing options)

  1. Fire Route 1 = Phone 1 Only 0 = Local

  1. = Phone 1

6 Non-Fire Route (Burg) 1 = Phone 1 Only 2 = Phone 2

3 = Both

7 Point Trouble Route 1 = Phone 1 Only

8 Restoral Route 0 = Local

9 Closing Route 0 = Local

10 Opening Route 0 = Local

11 Cancel Route 0 = Local

12 System Trouble Route 1 = Phone 1 Only

13 System Restore Route 0 = Local

14 Duress Route 1 = Phone 1 Only

15 Test Route 1 = Phone 1 Only

3. Reports Underlined = Default

  1. O/C Reports - All On 0 = No 0 = No

  1. = Yes

  2. O/C Reports - Part On 0 = No 0 = No

  1. = Yes

3 Restricted O/C Reports 0 = No 0 = No

(Opening after Alarm/Closing if Point is bypassed) 1 = Yes

4 Delay Alarm Report 0 0 to 255 seconds

5 Cancel Report 1 = Yes 0 = No

  1. = Yes

6 Restoral Reports 0 = No 0 = No

  1. = Yes

  2. = Delay

7 AC Fail Buzz/Report 2 = Buzz, Report 0 = No Buzz (Keypad), No Report

  1. = Buzz, No Report

  2. = Buzz Report

  3. = Buzz, Tag-Along Report

  4. = No Buzz, Report

  5. = No Buzz, Tag-Along Report

8 Point User Flag 0 = No 1 = Yes

0 = No

(Converts Point Numbers to D8112 style ZONEX Format, User ID's to D8112 style COMEX Format)

4. Receiver (4/2 Reporting only) Underlined = Default

  1. Receiver Format 1 = Modem II 0 = Pulse (4/2)

  1. = Modem II

  2. Fire Group 1 1 to 9, B to F

  3. Non-Fire Group 3 1 to 9, B to F

  4. Point Trouble Group 6 1 to 9, B to F

  5. Restoral Group 0 1 to 9, B to F

  6. Closing Group 0 1 to 9, B to F

  7. Opening Group 0 1 to 9, B to F

  8. Cancel Group D 0 to 9, B to F

  9. System Trouble Group 7 1 (71) Unsuccessful Download Attempt

2 Not Used

This is 1st digit 3 (73) Automatic Reset

Panel sends 1st digit here + 2nd digit listed here >>> 4 Not Used

5 Not Used

6 (76) Report Battery Missing

7 (77) Report Low Battery

8 (78) No AC Power

9 (79) Communication Fail Phone 1

B (7B) Communication Fail Phone 2

C (7C) RF Tamper

D (7D) RF Low Battery

E (7E) RF Receiver 7 Trouble

F (7F) RF Receiver 8 Trouble

  1. Sys Restore Group 8 1 (81) Successful Download Attempt

2 Not Used

This is 1st digit 3 (83) Panel Reset with Stand-By Switch

Panel sends 1st digit here + 2nd digit listed here >>> 4 Not Used

5 Not Used

6 Not Used

7 (87) Report Missing & Low Battery Restoral

8 (88) AC Power Restoral

9 (89) Communication Restoral Phone 1

B (8B) Communication Restoral Phone 2

C (8C) RF Tamper Restoral

D (8D) RF Battery Restoral

E (8E) RF Receiver 7 Restoral

F (8F) RF Receiver 8 Restoral

  1. Duress Group 9 1 to 3 Not Used

4 (94) 6 Invalid Passcode attempts

Panel sends 1st digit here + 2nd digit listed here >>> 5 (95) User Code 8 Duress

  1. Test Group 0 0 Disabled

  1. to 5 Not Used

6 Service Stop

7 Service Start

8 Test Report

5. Remote Programming Underlined = Default

  1. RAM Passcode 999999 0 to 9, A to F

  2. RAM Phone (BLANK) (19 digits)

  3. Answer Armed 0 0 to 15

  4. Answer Disarmed 0 0 to 15

  5. Answering Machine 1 = Yes 0 = No

  1. = Yes

6. Open/Close Underlined = Default

  1. Entry Delay Time 30 0 to 255 seconds

  2. Exit Delay Time 60 0 to 255 seconds

  3. Extended Delay Time 120 0 to 255 seconds

  4. Exit Tone 1 = Yes 0 = No

  1. = Yes

5 No Delay 1 = Part On 0 = Disabled

(Enables Part On Arming by pressing 0 twice) 1 = Part On

2 = All On

3 = Part and All On

6 Excursion 0 = Disabled 0 = Disabled

  1. = All Step

  2. = Part Step

  3. = All & Part Step

  4. = All Exit

  5. = Part Exit

  6. = All & Part Exit

  7. . A B C Keys (Panics) Underlined = Default

  1. A-Key Report (Police) 93 00 to 99, 00 = Default

  2. A-Key Alarm Output 2 = Steady Output 0 = No Output

  1. = Steady Output

  2. = Pulsed Output

  3. A-Key Ack Tone No 0 = No

  1. = Yes Keypad Ringback after signal

4 A-Key Text "A-Key"

5 B-Key Report (Medical) 92 00 to 99, 00 = Default

6 B-Key Alarm Output 0 = No Output 0 = No Output

  1. = Steady Output

  2. = Pulsed Output

7 B-Key Ack Tone No 0 = No

  1. = Yes Keypad Ringback after signal

8 B-Key Text "B-Key"

9 C-Key Report (Fire) 91 00 to 99, 00 = Default

(Also * on Keyfobs)

10 C-Key Alarm Output 1 = Pulsed Output 0 = No Output

  1. = Steady Output

  2. = Pulsed Output

11 C-Key Ack Tone No 0 = No

  1. = Yes Keypad Ringback after signal

12 C-Key Text "C-Key"

8. Bell Underlined = Default

  1. Bell Timer 6 0 to 255 minutes

  2. Bell Test (if Armed All ON) 0 = No 0 = No

  1. = Yes

3 Single Ring 0 = No 0 = No

  1. = 1 burg alarm output per arming period

4 Alarm on 2 Fail 0 = No 0 = No

  1. = Siren sounds after 2 failed comm attempts

9. Test Timer Underlined = Default

  1. Test Interval 3 = 28 Days 0 = No Report

  1. = 1 Day

  2. = 7 Days

  3. = 28 Days

2 Hours To Next Test report 0 0 to 23 hours

3 Minutes to Next Test Report 0 0 to 59 minutes

  1. Defer Test Report 1 = Yes 0 = No

  1. = No Test if any signal has sent during Test interval

10. Address Configuration Underlined = Default

  1. Address 1 ? 0 = Not Used

  2. Address 2 ? 1 = LED Keypad (D202A or D220A)

  3. Address 3 ? 2 = Text Keypad (D223)

  4. Address 4 ? 3 = Text Keypad with Points (D222)

  5. Address 5 ? 4 = 8 Point RF Expander (D208)

  6. Address 6 ? 5 = 16 Point RF Expander (D216)

  7. Address 7 ? 6 = Point Expander (D208 Expander)

  8. Address 8 ?

11. Point Codes (Zone Configuration) Default

  1. Point 1 2600A (Fire)

  2. Point 2 8820A (Delay)

  3. Point 3 8820A (Delay)

  4. Point 4 9820A (Instant)

  5. Point 5 7820A (Motion)

  6. Point 6 7820A (Motion)

  7. Point 7 7820A (Motion)

  8. Point 8 7820A (Motion)

Below are used with D208 Expander, D222 Keypad Points or D208RF/D216RF Wireless Receiver

  1. Point 9 0000A (Disabled)

  2. Point 10 0000A (Disabled)

  3. Point 11 0000A (Disabled)

  4. Point 12 0000A (Disabled)

  5. Point 13 0000A (Disabled)

  6. Point 14 0000A (Disabled)

  7. Point 15 0000A (Disabled)

  8. Point 16 0000A (Disabled)

  9. Point 17 0000A (Disabled)

  10. Point 18 0000A (Disabled)

  11. Point 19 0000A (Disabled)

  12. Point 20 0000A (Disabled)

  13. Point 21 0000A (Disabled)

  14. Point 22 0000A (Disabled)

  15. Point 23 0000A (Disabled)

  16. Point 24 0000A (Disabled)

Quick Zone Setups

2600A = Fire 7820A = Motion

8820A = Delay 5410A = Silent Panic

9820A = Instant 5910A = Audible Panic

  1. st Digit = Point Type

0 = Point Disabled 6 = Delay Zone

  1. = Fire Zone 7 = Interior Zone

  2. = Fire Zone w/Verification 8 = Delay Zone

  3. = Buzzer on Fault 9 = Instant Zone

  4. = 24 Hr Audible/Visible A = Keyswitch

  5. = 24 Hr Silent/Invisible B = Extended Delay All Arm

C = Extended Delay Part or All Arm

2nd Digit = Alarm Response

0 = No Response

  1. = Report Enabled

  2. = Report Enabled/Alarm Report Delay

  3. = Report Enable/Alarm Rep Dellay/Swinger Shutdown

  4. = Report Enabled/Swinger Shutdown

  5. = Alarm Output

  6. = Report Enabled/Alarm Output

  7. = Report Enabled/Alarm Report Delay/Alarm Output

  8. = Report Enabled/Alarm Report Delay/Swinger Shutdown/Alarm Output

  9. = Report Enabled/Swinger Shutdown/Alarm Output

3rd Digit = Special Point (Zone) Options

0 = Disabled

  1. = Trouble on Open

  2. = Trouble on Short

  3. = Trouble on Open or Short

  4. = Double Knock (2 Violations before Alarm)

  5. = Trouble on Open/Double Knock

  6. = Trouble on Short/Double Knock

  7. = Trouble on Open or Short/Double Knock

4th Digit = Device Address

0 = D2212 On-Board Points

  1. = Expansion Device on Address 1

  2. = Expansion Device on Address 2

  3. = Expansion Device on Address 3

  4. = Expansion Device on Address 4

  5. = Expansion Device on Address 5

  6. = Expansion Device on Address 6

  7. = Expansion Device on Address 7 < Use if RF Point

  8. = Expansion Device on Address 8 < Use if RF Point

5th Digit = Sensor Loop (Point Expander Loops only)

A = (Ignored)

B to P = Point Expander Loops labeled B to P

12. Point Text (for Text Keypads)

  1. Point 1 Text ??????

  2. Point 2 Text ??????

  3. Point 3 Text ??????

  4. Point 4 Text ??????

  5. Point 5 Text ??????

  6. Point 6 Text ??????

  7. Point 7 Text ??????

  8. Point 8 Text ??????

  9. Point 9 Text ??????

  10. Point 10 Text ??????

  11. Point 11 Text ??????

  12. Point 12 Text ??????

  13. Point 13 Text ??????

  14. Point 14 Text ??????

  15. Point 15 Text ??????

  16. Point 16 Text ??????

  17. Point 17 Text ??????

  18. Point 18 Text ??????

  19. Point 19 Text ??????

  20. Point 20 Text ??????

  21. Point 21 Text ??????

  22. Point 22 Text ??????

  23. Point 23 Text ??????

  24. Point 24 Text ??????

13. Relays

  1. Relay 1 Logic 0 = Function 1 Only 0 = Function 1 Only

  2. Relay 2 Logic 0 = Function 1 Only 1 = Function 1 or 2

2 = Function 1 and 2

  1. Relay 1 Function 1 0 = No Output 0 = No Output

  2. Relay 1 Function 2 0 = No Output 1 = Output on Point Alarm

2 = Output on Alarm Memory

  1. Relay 2 Function 1 0 = No Output 3 = Output on Point Trouble

  2. Relay 2 Function 2 0 = No Output 4 = Ouptut on Faulted Follow Point

5 = Output on Watch Tone

6 = Steady Output on A B C Key Activation

  1. = Pulsed Output on A B C Key Activation

  2. = Momentary Output on A B C Key

  3. = 10 Second Output on Disarm

  4. = Output follows Alarm Output

  5. = Output on All On Arming

  6. = Output on Part On Arming

  7. = Output on 3 Key Reset

  8. = Output on AC Failure

  9. = Output on Battery Trouble

  10. = Steady Output on Comm Failure

  11. = Output while Phone Seizure

  12. = Output for 900 ms for Ground Start

  13. = Output during Entry/Exit Delay

  14. = Output during Extended Delay

Must use with another function > 21 = Continuous Pulsed Output

Must use with another function > 22 = 2-second Output

23 = RF Light Key (on ITI Keyfobs)

24 = 2 second activation for 2-Way Module

14. User Test Underlined = Default

  1. User Bell Test Yes 0 = No

  1. = Yes

  2. User Battery Test Yes 0 = No

  1. = Yes

3 User Comm Test Yes 0 = No

  1. = Yes

15. Passcodes Underlined = Default

  1. Installer Code 654321 0 to 9, Blank

  2. Passcode Length ? 3 = 3-digit Passcode

4 = 4-digit Passcode

5 = 5-digit Passcode

6 = 6-digit Passcode

  1. Code 8 = Duress Yes 0 = No

  1. = Yes

4 Passcode Required No 0 = No

  1. = Passcode required to arm system

5 Change Passcode Owner 0 = Disabled

  1. = Owner can change Passcode

  2. = Owner & User can change Passcode

(On 5200 choose Passcode 1 to 8 then ENTER for below options)

User 1 Type Owner Owner / User / One Time

User 1 Passcode 123456 0 to 9, Blank

User 2 Type Disabled Owner / User / One Time

User 2 Passcode (Blank) 0 to 9, Blank

User 3 Type Disabled Owner / User / One Time

User 3 Passcode (Blank) 0 to 9, Blank

User 4 Type Disabled Owner / User / One Time

User 4 Passcode (Blank) 0 to 9, Blank

User 5 Type Disabled Owner / User / One Time

User 5 Passcode (Blank) 0 to 9, Blank

User 6 Type Disabled Owner / User / One Time

User 6 Passcode (Blank) 0 to 9, Blank

User 7 Type Disabled Owner / User / One Time

User 7 Passcode (Blank) 0 to 9, Blank

User 8 Type Disabled Owner / User / One Time

User 8 Passcode (Blank) 0 to 9, Blank

16. RF Parameters Underlined = Default

  1. RF Supervision Interval 24 0 = 12 Hours

  1. = 24 Hours

17. Program Lock Underlined = Default

  1. Return to Default No 0 = No

  1. = Yes

  2. Program Lock No 0 = No

(Prevents keypad programming) 1 = Yes

  1. Disable System No 0 = No

  1. = Yes