Radionics D4112 Program Sheet Click HERE for D5200 Programmer

Power Ratings 350mA Aux output

  1. 5A Siren output

Formats Modem II, BFSK, 4x2 1400 or 2300Hz

Modem Account numbers can be 4 digits, all other formats must be 3 digits

Download Info Panel will pick up depending on how many rings AnsArmRings and AnsDisRings are set at

or

Press Command 43 to cause panel to answer (if enabled)

Program Info Programming only by downloading, 5200 Programmer or 5100 "Wand" Programmer

Plug programmer in and momentarily short Reset Pin to Terminal 25 to enable program mode

Receiver Info If Radionics receiver C1 to C6 use Modem II Format with 4-digit Account

If Virtual Receiver use BFSK with 3-digit Account

Download Answer Command 43 will cause Panel to answer downloader call (if enabled)

  1. Account

Account # I _ _I _ _I _ _I _ _I (0 to 9, B to F)

(Virtual Receiver use 0 + 3-digit account number, for Radionics Receiver use 4-digit account)

Disable Sys I NO I No = Not Disabled, Yes = System shut down

Local I NO I No = Reporting, Yes = No Reporting

Entry Delay I _0 _I _3 _I _0 _I 10 to 120 seconds, Blank = No Entry Delay

BuzzACFail I NO I No = No Buzzer on AC Fail, Yes = Buzzer on AC Fail

Entry Delay I _0 _I _6 _I _0 _I 10 to 120 seconds, Blank = No Entry Delay

Prewarning I YES_I No = No Buzzer on Entry Delay, Yes = Buzzer on Entry Delay

Device1Type I _2 _I Keypad 1 Type BLANK = No Device

  1. = D611 LED keypad

Device1Type I _2 _I Keypad 1 Type 2 = D420 or D620 LED keypad

3 = D630 or D636 Alpha Keypad

  1. Passcodes

Passcode1 I _2 _I _3 _I _4 _I _5 _I 0 to 9

Passcode2 I _ _I _ _I _ _I _ _I 0 to 9

Passcode3 I _ _I _ _I _ _I _ _I 0 to 9

Passcode4 I _ _I _ _I _ _I _ _I 0 to 9

Passcode5 I _ _I _ _I _ _I _ _I 0 to 9, can be used as Duress if "Duress Type" enabled

User ID I NO I No = Disabled, Yes = Identify O/C Reports by User Passcodes

Passcode1 = Zone 1 Passcode4 = Zone 4

Passcode2 = Zone 2 Passcode5 = Zone 5

Passcode3 = Zone 3 RAM or Command 1 = Zone 9

Duress Code I _ _I 0 to 9 if BFSK format

0 to 9, B to F if Modem II format

Duress Type I PASSCODE + 1 I Passcode + 1, Passcode + 5

(To enable Duress User ID must be YES, Opening Report must be C, Closing Report must be C)

  1. Phone

PPrefix# I _1 _I _8 _I _0 _I _0 _I_ _I _ _I _ _I 8-digits 0 to 9 (Just put 1800)

C = 3 second pause D = 7 second Dial Tone pause

PPhone# I _? I _? I _? I _? I _? I _? I ? I 7-digits 0 to 9 (Rest of phone goes here)

APrefix# I_ _I _ _I _ _I_ _I _ _I _ _I_ _I _ _I _ _I (Alternate Phone, not used)

APhone# I_ _I _ _I _ _I_ _I _ _I _ _I_ _I _ _I

DTMF Dial I YES_I No = Pulse Dialing, Yes = DTMF Dialing

CS Format I _ ? _I 7 = Radionics Modem Format

6 = Radionics BFSK Format

5 = Radionics Single Round with Parity

Use 7 if Radionics C Receiver 4 = Ademco High Speed Double Round

3 = Silent Knight High Speed Double Round

Use 6 if on Virtual Receiver 2 = Ademco Low Speed Double Round

  1. = Silent Knight Low Speed Double Round

1400 Hz Ack I NO I No/Yes (Default) Always leave at No

2300 Hz Ack I _ ? _I No/Yes (Default) Yes if using Virtual Receiver

No if using Radionics C Receiver

AlarmRoute I _ 1 _I Default = 0 0 = Primary Phone Only

  1. = Primary then Secondary Phone

OP/CL Route I _ 0 _I Default = 0 2 = Alternate then Primary Phone

3 = Primary - Not designated

Trouble Route I _ 1 _I Default = 0 Secondary - Designated

Restore Route I _ 0 _I Default = 0

4. Remote Program

Passcode I _9 _I _9 _I _9 _I _9 _I 4-digits 0 to 9, B to F

Blank = No Remote Access

AnsArmRings I _0 _I 5 _I 0 (Default) to 14 Rings

Blank = No Answer

AnsDisRings I _1 _I 2 _I 0 (Default) to 14 Ring

Blank = No Answer

5. Tbl/Restorals

Trouble Code I _F _I 0 to 9, B to F, Blank (F is automatic if BFSK or Modem II is used)

Restoral Code I _E _I 0 to 9, B to F, Blank (E is automatic if BFSK or Modem II is used)

Expanded T/R I NO I No/Yes (Default) (Transmit Expanded Trouble & Restorals)

DelayRestore I NO I No (Default)/Yes (Delays Restorals until Siren Timeout)

6. Open/Closings

Opening Code I _ _I 0 to 9, B to F, Blank (B = Default)

Closing Code I _ _I 0 to 9, B to F, Blank (C = Default)

Restrict O/C I NO I No (Default)/Yes (Open after Alarm, Close if Force Armed)

Cancel Code I _ _I 0 to 9, B to F, Blank (Leave Blank)

7. Bell Options

Bell Time I _ 0 _I _ 6 _I 00 to 63 minutes (Default = 06)

Test Bell I NO I No (Default)/Yes (Bell Test after Armed)

One Ring I YES_I No (Default)/Yes (1 alarm per zone during Arming period)

8. Cmd Options

Cmd1MstrArm I YES_I No/Yes (Default) (Enable Command 1 Arming (Quick Arm))

Cmd2InstPer I YES_I No/Yes (Default) (Enable Command 2 Arming (Instant Arm))

Cmd3DlyPer I YES_I No/Yes (Default) (Enable Command 3 Delayed Perimeter Arming)

Cmd5PassChg I YES_I No/Yes (Default) (Enable Command 5 (Passcode Change Mode)

Cmd6PerWatch I YES_I No/Yes (Default) (Enables Command 6 (Door Chime Mode)

Cmd8PerPartl I YES_I No/Yes (Default) (Enable Command 8)

(Perimeter Arm with Entry/Exit Delay)

(Partial Arming by bypassing open zones)

Cmd0ZnBypass I YES_I No/Yes (Default) (Force Arm with Passcode & Command 1, 2, 3)

Force Arming I YES_I No/Yes (Default) (Enable Command 0 for Bypass while Arming)

ForceArm Max I _ 1 _I 1 = Default 0 to 6 (Maximum Number of Zones for Force Arming)

9. Sys Test/Reset

Cmd41RstRpt I NO I No (Default)/Yes (Enable Command 41 Expanded Restorals)

Cmd42DiagRpt I NO I No/Yes (Default) (Enable Command 41 Expanded Restorals)

Cmd44SysTst I NO I No/Yes (Default) (Enable Command 44 to send Test signal)

(if No will also disable "A" Function key)

Cmd47SmkRst I YES_I No/Yes (Default) (Enable Command 47 to reset smoke detectors)

(if No will also disable "B" Function key)

Battery Supv I _ 9 _I 0 to 9, B to F, Blank (Enables Low Battery Reports)

(9 = Trouble & Restore Zone 9)

10. Special Cmds

Cmd7RptCode I _ 7 _I 0 to 9, B to F, Blank (Command 7 Alarm Report Code)

Cmd7Bell I NO I No (Default)/Yes (No Siren/Bell on Command 7 Medical Alarm)

Cmd7PlsBell I NO I No (Default)/Yes (No Pulsed Siren/Bell on Command 7 Medical Alarm)

Cmd7AltAlrm I NO I No (Default)/Yes (No Alternate Alarm on Command 7 Medical Alarm)

Cmd9RptCode I _ 9 _I 0 to 9, B to F, Blank (Command 9 Alarm Report Code)

Cmd9Bell I YES_I No (Default)/Yes (Enable Siren/Bell on Command 9 Fire Alarm)

Cmd9PlsBell I YES_I No (Default)/Yes (Enable Pulsed Siren/Bell on Command 9 Fire Alarm)

Cmd9AltAlrm I NO I No (Default)/Yes (Activate Alternate Alarm on Command 9 Fire Alarm)

11. Zone Codes

Show Zones I YES_I No/Yes (Default) (Shows Zone Status while Disarmed)

Default Default Zone Type (00000 if Zone not used)

Zone1 Code I _0 _I _1 _I _4 _I _5 _I _4 _I Fire, Trouble and Restorals

Zone2 Code I _2 _I _6 _I _1 _I _5 _I _0 _I Perimeter Delay, Trouble and Restorals

Zone3 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals

Zone4 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals

Zone5 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals

Zone6 Code I _1 _I _2 _I _1 _I _5 _I _0 _I Interior Instant, Trouble and Restorals

Digit 1 = Zone Type

0 = 24 Hour Zone

  1. = Interior Zone

  2. = Perimeter Zone

  3. = Priority 24 Hour Zone

  4. = Priority Interior Zone

  5. = Priority Perimeter Zone

Digit 2 = Response to Open or Short

0 = No Trouble, No Delay, Instant Alarm on Open or Short

  1. = Trouble on Open, Instant Alarm on Open or Short

  2. = Trouble on Short, Instant Alarm on Open or Short

  3. = Trouble on Open or Short, Instant Alarm on Open or Short

  4. = Delay on Open, Instant Alarm on Short, no Trouble Conditions

  5. = Delay on Open, Instant Alarm on Short, Trouble on Open

  6. = Delay on Open, Trouble on Short, Instant Alarm on Short

  7. = Delay on Open, Trouble on Open or Short, Instant Alarm on Short

  8. = Delay on Short, Instant Alarm on Open, no Trouble Conditions

  9. = Delay on Short, Instant Alarm on Open, Trouble on Open

A = Delay on Short, Instant Alarm on Open, Trouble on Open

B = Delay on Short, Instant Alarm on Open, Trouble on Open or Short

C = Delay on Open or Short, no Trouble Conditions

D = Delay on Open or Short, Trouble on Open

E = Delay on Open or Short, Trouble on Short

F = Delay on Open or Short, Trouble on Open or Short

Digit 3 = Zone Alarm Local Response

0 = Silent Alarm, No Alarm Output

  1. = Steady Alarm Output for Bells/Sirens

  2. = Alternate Alarm Output Activation for Duration of Bell Timeout

  3. = Alternate Alarm Output Activation and Steady Alarm Output for Bells/Sirens

  4. = Pulsing Alarm Output for Bells/Sirens (Overrides single Bell per fault option)

  5. = Alternate Alarm Output Activation (Overrides single Bell per fault option)

  6. = Alternate Alarm Output Activation and Pulsing Alarm Output for Bells/Sirens

Digit 4 = Central Station Reporting Options

0 = Non-Reporting, Local Zone only

  1. = Standard Reporting Zone

  2. = Designated Zone

  3. = Swinger Shunt Zone

  4. = Swinger Shunt, Designated Zone

  5. = Standard Reporting Zone, Includes Restoral Reports

  6. = Restoral Reports, Designated Zone

  7. = Restoral Reports, Swinger Shunt zone

  8. = Designated Zone

Digit 5 = Local Zone Annunciation and Options

0 = No Options

  1. = Invisible Zone

  2. = Ring Siren/Bells until Zone Restoral

  3. = Ring Siren/Bells until Zone Restoral, Invisible Zone

  4. = Sound Buzzers for Zone Fault

  5. = Sound Buzzers for Zone Fault, Invisible Zone

  6. = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral

  7. = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral, Invisible Zone

12. Test Reports

TestPrimary I NO I No/Yes (Default) (Transmit Test Reports to Primary Phone)

TestAlternate I NO I No (Default)/Yes (Transmit Test Reports to Alternate Phone)

Test Code I_ _I _ _I 0 to 9 if BFSK format (Test Report Code, Blank = disabled)

0 to 9, B to F if Modem II format

Test Code E I NO I No (Default)/Yes (Transmit Automatic Test Report Code)

Interval I 1 _I 0 to 63, Default = 1 (Test Time in Days)

IntervalDays I YES_I No/Yes (Default) (No = Test Time in Hours, Yes = In Days)

DaysTilRpt I _I _I 0 to 63, Default = 1 (Number of Days until 1st Test Report)

HoursTilRpt I _I _I 0 to 63, Default = 1 (Number of Hours until 1st Test Report)

Defer Test I NO I No (Default)/Yes (Defer Test Reports when an Alarm Generated)